background image

www.GreenSeriesFitness.com

 

 

 

©May 2015 

 

 

Call Toll free (800) 269-7140 

CIR-TM6000DC-G   Revision 1.1

 

 

1.  Information for Components & System 

1.1. 

System Wiring Diagram

 

 

 

 

 

Summary of Contents for CIR-TM6000DC-G

Page 1: ...www GreenSeriesFitness com May 2015 Call Toll free 800 269 7140 CIR TM6000DC G Revision 1 1 1 SERVICE MANUAL PRODUCT TREADMILL CIR TM6000DC G...

Page 2: ...rd Function 7 3 3 Real Speed Does Not Match with Display Speed 7 4 Engineering Mode 4 1 Engineering Mode ONE Basic Settings 8 4 2 Engineering Mode TWO Used Information Management 8 4 3 Engineering Mod...

Page 3: ...www GreenSeriesFitness com May 2015 Call Toll free 800 269 7140 CIR TM6000DC G Revision 1 1 3 1 Information for Components System 1 1 System Wiring Diagram...

Page 4: ...Decreasing speed pilot lamp Yellow Flashing while decreasing speed D4 Motor start pilot lamp Yellow Lights up while motor has power D5 Incline motor up pilot lamp Yellow Lights up while incline motor...

Page 5: ...2 3 4 5 6 7 8 9 10 11 12 Define 5V ADC GND Down Up RPM 5V Motor EN Slow Fast GND 12V Definition of J1 ISP Program Updater Connector Pin 1 2 3 4 Define 5V ADC GND Down Definition of JK2 SAFET Connector...

Page 6: ...all Toll free 800 269 7140 CIR TM6000DC G Revision 1 1 6 Definition of JK5 HP Connector Pin 1 2 3 4 Define VCC GND Output 12V Definition of JK7 8 Fan Connector Pin 1 2 Define PWM GND Definition of JK9...

Page 7: ...ables have not been damaged during assembly Determine Cause and Solution SPEED ERROR Turn OFF the AC power and wait 10 seconds Turn ON the AC power Press START Is the running belt moving No Open the m...

Page 8: ...ter the engineering mode displays MANUAL INC XXX XXX Incline parameter Did the incline move while pressing the incline UP or DOWN key A No Did the D5 or D6 lamps illuminate while pressing the incline...

Page 9: ...ght Open the console and refer to page 6 and measure the voltages of Pin 11 and 12 of the upper console Does it have 12V power Yes Replace the console wire No Yes Replace the console PCB Did all keys...

Page 10: ...The D2 or the D3 lamps on the motor controller should flash during the increase or decrease of speed Replace the console PCB Check the console wires They should not be crushed pinched or cut Refer to...

Page 11: ...0 press Speed Fast or Speed Slow to set the min speed setting range 8 25KPH 5 15 5MPH press Enter to confirm and back to idle mode 4 2 Engineering Mode 2 Used Information Management Pull out the safe...

Page 12: ...incline position press Start wait for a beep sound to save the max incline parameter message window show MAX AD OOO XXX the OOO and XXX value will the same after saving press Enter to confirm and to...

Page 13: ...pe select ISP 5 2 3 2 MCU Part No select 82 Series MG82FL E 564 5 2 3 3 Load burning code and update programmer select Load File and then select AP Code then press OK Select and open the burning code...

Page 14: ...on 1 1 14 5 3 2 Connect the programmer to J1 ISP of the console PCB 5 3 3 Turn ON the AC power and then press the update button to update the program Update button 5 3 4 Please remove the programmer a...

Reviews: