background image

P

rote

K

t

IP66 Rated Weatherproof 

Enclosure

- PENC1G & PENC2G

PowerBreaker Protekt products are suitable for use 

outdoors in severe conditions of rain and water spray as 

well as dust contamination to IP66 as defined by BS EN

60529. Designed for use with products rated 230V - 50Hz.

INSTALLATION GUIDE - IMPORTANT

This product should be installed by a competent  person

and in accordance with the current IET Wiring Regulations. 

If in doubt, consult a qualified electrician

Important -

•      Always disconnect the mains supply via the switch in 

        the main fuse board or consumer unit before 

        commencing any electrical work. 

•      Ensure that all terminal screws are fully tightened and 

        that earth wires are sleeved and that no bare 

        wires are showing.

•      Cable glands must be used which maintain the IP 

        rating. The warranty is invalid if IP rating is not 

        maintained.

PENC1G & PENC2G 

Installation Instructions

The IP66 rating can only be achieved when the cover is

pressed down firmly so that any cable runs through the 

centre of the cable outlet, and is fully enclosed by the

special seal. Always ensure that the cover is located

correctly in place. If in doubt, consult a qualified electrician.  

1.     Ensure that mounting surface is flat and free from loose 

        particles and dirt.

2.     Lift the lid then remove the upper portion from the back

        box by removing the 4 screws on installation. Please 

        note that it is  important to use a screwdriver of a size 

        that allows you to properly tighten these screws on 

        installation.

3.     If necessary take the back box and drill a small hole 

        through the drainage point that will be at the lowest 

        point when mounted. This is necessary to ensure that 

        any residual moisture or condensation has an escape 

        route at the back of the box.

4.     Use a suitable drill/wall plug for the surface on which 

        you are mounting your weatherproof enclosure and 

        use  No.8 countersunk screws (not supplied) to secure 

        the back box through the 4 corner holes.

5.     Remove a suitable cable entry cover by pushing 

        through from the inside of the back box. If 

        circumstances permit the best entry point for the 

        supply cable is the bottom one.

6.     If cable entry is via 20mm conduit use the conduit 

        gland to secure the conduit to the back box. If entry of 

        cable is to be direct use a suitable IP rated cable 

        gland.

Opening the lid

To open the lid use your thumbs to un-clip the end snap-shut

clips. The lid should then pop open.

Snap-Shut Clips

(Lift to open)

Snap-Shut Clips

(Lift to open)

Reviews: