To set temporary override program temperature:
This function allows you to temporarily override the CT
temperature from the ET temperature settings, until next CT
setting (or vice versa).
Program temperature setting until next ET setting.
The unit is running at CT program period. Press
to change from
CT to ET setting (until the next CT program period).
The unit is running at ET program hour. Press
to change from
ET to CT setting (until next ET program hour).
To set vacation or permanent override Temperature:
This function allows you to set your vacation temperature from
1
to
99
days or to set a permanent override temperature forever.
Press
key the two bars “
” will flash under “SA SU” Press
or
key to select the number of days for your vacation period.
The maximum selection is up to
99
days. If you choose
the
period will be permanent override. Press
key to confirm the
vacation period.
Press
or
key to select temperature. Press
key to confirm
the override setting.
To cancel manual, temporary, vacation or permanent
override:
Press
or
key to return into running mode. Or press
key to
turn off the unit.
To switch the unit ON and OFF:
Press
key to turn off from on. Press
key to turn on from off.
To reset the unit:
Press the Reset key to reset the unit into initial clock setting mode.
All previous programs will reset to factory preset settings.
Sensor:
This thermostat (THP
1
-C) uses the most advance temperature
sensing element located on the lower right side of the cast under
the grill. If the sensor is touched accidentally you must allow few
minutes for sensor to come back to normal temperature.
The temperature is measured every minute.
WEST
ROAD,
HARLOW
ESSEX,
CM
20
2
BG,
UK
s a l e s @ g r e e n b r o o k . c o . u k
w w w . g r e e n b r o o k . c o . u k
Is
s
u
e
n
o
:
7
0
2
0
3
4
Mode
Air-conditioning
Heating
23
o
c
20
o
c
28
o
c
17
o
c
DIP SWITCH 1 - SWING CYCLE -
ON
=
0.2
O
C
OFF
=
0.5
O
C
DIP SWITCH 2 - HEATING OR AIR-CONDITIONING
System setting
ON = AIR CONDITIONING
OFF = HEATING
Important
Note: Do not set the beginning and end of the program to
0
:
00
due to the thermostat needing this time for its reference use.
Therefore you must set the beginning or end time at
23
:
00
or
01
:
00
.
To view and change
or
temperature:
The CT and ET temperature is preset to the temperatures in the
below table for heating and air-conditioning mode:
Press
key to view CT and ET temperature mode.
Press
to change the viewing of CT setting from ET setting
or press
key to change the viewing of ET setting from CT
setting. The temperature is flashing at this moment. Press
or
key to change CT or ET setting. Press
key to confirm the
setting and return to running mode.
To set temporary manual override temperature:
This function allows you to change the present temperature
setting to a temporary temperature setting from next
1
hour up
to
48
hours. Press
or
to enter the manual override
temperature mode and temperature is flashing.
Press
or
key to select override temperature. Press
key
to confirm temperature setting.
H
1
will be flashing.
Press
or
key to select hours for overriding time.
The maximum hours are
48
. Press
key to confirm setting.
Note: The first hour of override (H
1)
will only run for maximum
45
minutes. However from the second hour onwards will run
for full hour timing. e.g. If you select
2
hours override the
maximum time of override will be
1
hour and
45
minutes.
Press
key. The Monday preset program at
0.00
is on display.
Press
or
key the display will show the temperature setting
in each hour. e.g. Monday program show
0:00
-
5:59
and
8:00
-
15:59
are set at Economy temp.,
6:00
-
7:59
and
16:00
-
22:59
is
set at CT(Comfort temp). Note
23:00
-
0:00
is set at ET
(Economy temp).
Press
key the next day preset program is displayed. Again
Press
or
key. This will show the temperature setting at each
hour. Repeat above steps, each preset program will display until
Sunday. Once Sunday program has been reviewed. Press
key.
The display will return into running mode.
To change preset program:
The preset program may not be suitable for some families but
the program may be adjusted to suit your living life style.
The following instructions will allow you to change the preset
program.
Press
key to enter into program viewing mode.
Press
key to select the day of program to make a change.
Press
or
key to select the hour to make change. Press
or
to select the temperature to make change. e.g. To change
Saturday
12:00
-
16:59
from CT to
12:00
-
16:59
ET.
1
.
Press
key to enter into program viewing mode.
2
.
Press
key to select the day to Saturday program.
3
.
Press
key until
12:00
with CT setting.
4
.
Press
key to change CT period to ET period.
5
.
Repeat step
3
&
4
to change
13:00
-
14:00
from CT period to
ET period.
6
.
Press
key to confirm setting. Press
key to return into
running mode.
TECHNICAL DATA
Temperature range:
5-30
o
C
Differential:
+/-
0.5
o
C from set temperature.
Temperature accuracy:
+/-
0.5
o
C
Batteries:
2
x AA (
1.5
VDC) size batteries
Receiver Rated switching
230
V,
50Hz
AC resistive load,
power:
5
A Inductive load
Minimum on time in
heating mode:
1
minute
Minimum off time in
air-conditioning mode:
3
minutes
RF Frequency:
433
MHz
User Optional Selection:
Lever off the the back panel to reaveal the circuit board, the DIP
SWITCH is where the user can select following option:
Fig 4.2