background image

To set temporary override program temperature:

This function allows you to temporarily override the CT
temperature from the ET temperature settings, until next CT
setting (or vice versa).

Program temperature setting until next ET setting.
The unit is running at CT program period. Press

to change from

CT to ET setting (until the next CT program period).
The unit is running at ET program hour. Press

to change from

ET to CT setting (until next ET program hour).

To set vacation or permanent override Temperature:

This function allows you to set your vacation temperature from

1

to

99

days or to set a permanent override temperature forever.

Press

key the two bars “

” will flash under “SA SU” Press

or

key to select the number of days for your vacation period.

The maximum selection is up to

99

days. If you choose

the

period will be permanent override. Press

key to confirm the

vacation period.
Press

or

key to select temperature. Press

key to confirm

the override setting.

To cancel manual, temporary, vacation or permanent

override:

Press

or

key to return into running mode. Or press

key to

turn off the unit.

To switch the unit ON and OFF:

Press

key to turn off from on. Press

key to turn on from off.

To reset the unit:

Press the Reset key to reset the unit into initial clock setting mode.
All previous programs will reset to factory preset settings.

Sensor:

This thermostat (THP

1

-C) uses the most advance temperature

sensing element located on the lower right side of the cast under
the grill. If the sensor is touched accidentally you must allow few
minutes for sensor to come back to normal temperature.
The temperature is measured every minute.

WEST

ROAD,

HARLOW

ESSEX,

CM

20

2

BG,

UK

s a l e s @ g r e e n b r o o k . c o . u k

w w w . g r e e n b r o o k . c o . u k

Is

s

u

e

n

o

:

7

0

2

0

3

4

Mode

Air-conditioning

Heating

23

o

c

20

o

c

28

o

c

17

o

c

DIP SWITCH 1 - SWING CYCLE -

ON

=

0.2

O

C

OFF

=

0.5

O

C

DIP SWITCH 2 - HEATING OR AIR-CONDITIONING

System setting

ON = AIR CONDITIONING
OFF = HEATING

Important

Note: Do not set the beginning and end of the program to

0

:

00

due to the thermostat needing this time for its reference use.
Therefore you must set the beginning or end time at

23

:

00

or

01

:

00

.

To view and change

or

temperature:

The CT and ET temperature is preset to the temperatures in the
below table for heating and air-conditioning mode:

Press

key to view CT and ET temperature mode.

Press

to change the viewing of CT setting from ET setting

or press

key to change the viewing of ET setting from CT

setting. The temperature is flashing at this moment. Press

or

key to change CT or ET setting. Press

key to confirm the

setting and return to running mode.

To set temporary manual override temperature:

This function allows you to change the present temperature
setting to a temporary temperature setting from next

1

hour up

to

48

hours. Press

or

to enter the manual override

temperature mode and temperature is flashing.
Press

or

key to select override temperature. Press

key

to confirm temperature setting.
H

1

will be flashing.

Press

or

key to select hours for overriding time.

The maximum hours are

48

. Press

key to confirm setting.

Note: The first hour of override (H

1)

will only run for maximum

45

minutes. However from the second hour onwards will run

for full hour timing. e.g. If you select

2

hours override the

maximum time of override will be

1

hour and

45

minutes.

Press

key. The Monday preset program at

0.00

is on display.

Press

or

key the display will show the temperature setting

in each hour. e.g. Monday program show

0:00

-

5:59

and

8:00

-

15:59

are set at Economy temp.,

6:00

-

7:59

and

16:00

-

22:59

is

set at CT(Comfort temp). Note

23:00

-

0:00

is set at ET

(Economy temp).
Press

key the next day preset program is displayed. Again

Press

or

key. This will show the temperature setting at each

hour. Repeat above steps, each preset program will display until
Sunday. Once Sunday program has been reviewed. Press

key.

The display will return into running mode.

To change preset program:

The preset program may not be suitable for some families but
the program may be adjusted to suit your living life style.
The following instructions will allow you to change the preset
program.
Press

key to enter into program viewing mode.

Press

key to select the day of program to make a change.

Press

or

key to select the hour to make change. Press

or

to select the temperature to make change. e.g. To change

Saturday

12:00

-

16:59

from CT to

12:00

-

16:59

ET.

1

.

Press

key to enter into program viewing mode.

2

.

Press

key to select the day to Saturday program.

3

.

Press

key until

12:00

with CT setting.

4

.

Press

key to change CT period to ET period.

5

.

Repeat step

3

&

4

to change

13:00

-

14:00

from CT period to

ET period.

6

.

Press

key to confirm setting. Press

key to return into

running mode.

TECHNICAL DATA

Temperature range:

5-30

o

C

Differential:

+/-

0.5

o

C from set temperature.

Temperature accuracy:

+/-

0.5

o

C

Batteries:

2

x AA (

1.5

VDC) size batteries

Receiver Rated switching

230

V,

50Hz

AC resistive load,

power:

5

A Inductive load

Minimum on time in
heating mode:

1

minute

Minimum off time in
air-conditioning mode:

3

minutes

RF Frequency:

433

MHz

User Optional Selection:

Lever off the the back panel to reaveal the circuit board, the DIP
SWITCH is where the user can select following option:

Fig 4.2