p. 30/48
Figure 5.9.
Menu item „EFFECT LEVEL” – choice of the operating thermal capacity stage
of the pellet burner of series “GP IV”.
In this menu item the operating thermal capacity stage of the burner is chosen and the burner
will operate at this stage until the set-point is reached, followed by thermal capacity
modulation.
In the following table are presented the factory defined thermal capacity stages and their
corresponding thermal capacity of the pellet burner of series “GP IV”.
Thermal capacity of the pellet burner , [kW]
Model
GP 25 IV
GP 32 IV
Thermal capacity stage
-
-
1
7.0
10.0
2
15.0
20.0
3
20.0
25.0
4
25.0
32.0
5
28.0
35.0
Table 5.1.
Operating thermal capacity of the pellet burner of series „GP IV”, according to
their specific model;
NOTE
:
It is highly recommended to exploit the pellet burner of series “GP IV” at thermal
capacity stage not exceeding the 4
th
including, the 5
th
thermal capacity stage is designed to
operate only in high heat consumption rates for short periods of time
;
In order to chose the menu item „EFFECT LEVEL” one should press the button,
below ENTER – button „S”. In order to go into another menu item, one should press the “+”
button, found below the displayed arrow. Use the button „ESC „ in order to return to upper
menu level and going back to the main menu item.
At entering the menu item „EFFECT LEVEL” the end user could choose one of the five
operating thermal capacity stages available at set as thermal capacity set-point of the
automatic pellet burner of series “GP IV”.
Еffect level
[n]
O:5
N:5