p.
41/48
burner should be performed by restarting the power supply of the main module of
the pellet burner;
ATTENTION :
regular cleaning of burner will ensure long-life reliable exploitation period,
economic and efficient performance of the unit;
5.11.
Safety and unexpected risks
Risks could arise at the exploitation of the burner of series “GP”:
The automatic pellet burner “GP” is designed according to the safety requirements of the
operating European standards and norms. However safety and unexpected risks could arise in
situations like following:
The pellet burner of series “GP” is operating incorrectly/abnormally;
The unit is installed by unauthorized/unqualified personal;
The safety instructions, described in this manual are not followed and fulfilled;
Unexpected risks:
The pellet burner of series „GP” is designed and produced according to the requirements of
the operating EU safety norms. However, in spite of that possible risks are considered as a
result of the operating process of the pellet burner, it is possible to arise risks as follows:
Cauterization risks
, caused by high temperatures, as a result of the combustion process
in the combustion chamber, at manual cleaning processes of the surfaces of the burner
(i.e. its combustion chamber), or ash residue cleaning, or any unburned fuel material,
smoldering on the grate of the combustion chamber;
Electrical shock risks
at indirect contact. The burner is connected to the power supply
and its operating modules are separated in a section of its main module, equipped with
required protective and short-circuit preventive elements. It is obligatory to perform by
authorized personal/technician the burner ground connection. It is forbidden to remove
the cover of the main unit of the burner, as well as the protective cover of the electric
motor of the fuel transport auger, by unauthorized person;
Fingers injuring risks
at operating mode or at maintenance and cleaning process of the
burner. It is recommended to use appropriate individual resources for self-protection;
Suffocation risks
due to flue gas uncontrolled emissions, in case when the chimney
draught is insufficient, in case that the flue gas duct (of the heat consumer unit) is
clogged, or in case that the flue gas duct is not fully tightened and gas leaks are
possible;