page 38/47
5.3.3. ADJUSTMENT OF PARAMETERS FOR SUPPLYING THE HEATING AIR
FUNNEL SYSTEM.
If the air funnels distribution system has installed elements for regulation of the operation mode
(air flow direction and flow rate control), then the operating parameters of the heated air passing
through this elements can be adjusted. The heated air temperature can be changed also by
adjustment of the generator heating output.
EXPLANATION: It is recommended to perform this process smoothly and gradually, which can
ensure the expected distribution of heat energy, provided by the co-operation of the appliance and
the air funnels distribution system.
5.4.
STOPPING THE GENERATOR OPERATION.
Stopping the appliance operation can be performed by using the switch “START”. Recovering the
generator operation can be performed by switching on the same switch. In case operation is not
further necessary, the appliance must be cleaned from the ash deposits over its heated surfaces.
WARNING: In case the generator operation is no further needed, then entire ash cleaning from its
heat exchanging surfaces must be performed, because of their corrosive influence over the steel
components, which decreases the generator body life time. At the end of the heating season it is
also necessary to perform prophylaxis by specialized servicing company. Observing these
procedures ensures long term life cycle and reliable operation of the generator.
5.5.
GENERATOR SWITCH OFF.
WARNING: The appliance switching off can be performed by positioning the switch “START” in its
initial position – “switch off”. This is the recommended method of switching off, because it
performs the so called “controlled switch off”, during which the fans operate and the emergency
signals are controlled by the generator control module. After the generator cools down it must be
switched off by the “POWER” button, which is located on the appliance control board. It is also
recommended to clean the appliance from the ash deposits.
It is forbidden to stop the generator by the button “POWER” during operation!
•
Emergency stopping of the generator
During the generator operation it is possible that emergency situations occur, which will lead
to the generator emergency mode. Some of these situations are identified by the appliance
controller, as it automatically starts preventing procedures. An information messages appear
on the appliance control module, which inform the customer about the emergency type,
accompanied with a light lamp indication – “ALARM”, positioned on the generator control
board;
If emergency situation occurs, then the information message should be read/checked
and following measures should be taken.
After the generator cools down to the ambient temperature it is necessary to identify the
reason for the emergency and to ask for servicing assistance.
After that the generator operation has to be restarted, by switching off and on the “POWER”
button.