Ceiling Exhaust and Inline Fans

Converting from ceiling to cabinet design for Model SP fans

All SP convertible sizes will be shipped with grille and duct collar cover.

Conversion Kit Parts List

 

• Qty. of 1 Blower Box Cover

Tools Required

 

• Phillips Head Screwdriver

Step 1:   Remove grille (A) by removing the two 

grille screws (B).

Step 2:   Remove duct collar cover (C) by 

removing the four duct collar screws (D).

Step 3:   Discard grille (A), two grille screws (B), 

and duct collar cover (C).

Step 4:   Remove the six (6) tinnerman clips (E) 

by twisting them to one side and pulling 
straight out. Discard two of the six 
tinnerman clips.

Step 5:   Insert the remaining four tinnerman clips 

(E) on grille opening side.

Step 6:   Place blower box cover (F) over 

tinnerman clips (E), which were inserted 
in step 5.

Step 7:   Screw the blower box cover (F) into place 

with four blower box cover screws (D).

B

A

C

E

D

D

F

E

SP/CSP models shown are 
UL and cUL listed E 33599 

Attach the Grille

1. If lighted grille is being used, plug wire into fan 

socket.

  If lighted grille and ceiling radiation damper are 

being used, plug wire from lighted grille into ceiling 
radiation damper socket. Do not plug wire directly 
into the fan socket. Make sure the wire does not 
interfere with the ceiling radiation damper operation.

2. Attach grille with two screws provided. Make sure 

not to over tighten; over tightening will damage 
grille.

3. Slide attachment screw covers over the attachment 

screws, shown in Figure 8 and 9.

4. If lighted grille is being used, install light bulb(s) into 

light socket(s). For incandescent lights, use maximum 
100 watt bulb (by others). For fluorescent lights, use 
27W GU24 bulbs. Greenheck has replacement 27W 
GU24 bulbs call 1-800-355-5354 to order.

5. If lighted grille is being used, snap lens into place, by 

pushing on the outside edges of lens, shown in Fig. 9. 
To remove lens, use small screw driver and pry on 
one side of lens.

6. Turn on power and check fan and light operation.

Fig. 9

Fig. 8

Squeeze 
tabs to 
insert/remove lens

®

Summary of Contents for CSP

Page 1: ...necting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction Sufficient air is needed for proper co...

Page 2: ...A Models Only A 50 500 710 780 Models Remove the two screws holding the power assembly in and pull power assembly out Rotate power assembly 180 degrees and put back into fan Use the same screws to reattach power assembly to fan housing Flip fan over and remove the four screws holding the discharge duct and damper assembly Exchange the assembly with plate mounted on top of fan as shown in these ill...

Page 3: ...iation damper has an electrical plug in it The electrical plug must be inserted into the fan Make sure the electrical wire will not interfere with damper operation as shown in figure below Discharge Installation SP A 50 90 Models A 50 510 710 780 Models Wires from lighted grille Wires to ceiling fan Do not allow interference in this area A 700 900 1550 Models SP A Box Slot Plastic SP A Duct Adapter...

Page 4: ...two SP B mounting tabs fully engage into the two SP B box mounting slots 1 2 OPTIONAL Align the pins on the TR 6x4 adaptor to the duct pin hole on the SP B 6 inch duct Push until the adaptor snaps into place 3 SP B Box Scroll Slots SP B Box Mounting Tabs SP B Box Mounting Slots TR 6x4 Pin TR 6x4 PN 473324 SP B 6 inch Plastic Duct PN 474433 SP B Plastic Duct Pin Hole SP B Box Scroll Tabs ...

Page 5: ...height is determined shown in Fig 2 Cut hole to dimensions shown in table below 3 Installation of ductwork is critical to the performance of the fan shown in Fig 5 Straight ductwork 1 or ductwork that turns in the same direction as the wheel 2 is recommended Ductwork turning opposite the wheel direction 3 will cause turbulence and back pressure resulting in poor performance 4 Slide ductwork over t...

Page 6: ...wn are UL and cUL listed E 33599 Attach the Grille 1 If lighted grille is being used plug wire into fan socket If lighted grille and ceiling radiation damper are being used plug wire from lighted grille into ceiling radiation damper socket Do not plug wire directly into the fan socket Make sure the wire does not interfere with the ceiling radiation damper operation 2 Attach grille with two screws ...

Page 7: ... cleaned periodically to maintain performance Greenheck offers washable aluminum mesh filters specifically designed for these fans Please consult our SP CSP catalog for more information Flex Duct Connections Fiberglass Ductboard Remote Mounted Correct Low Sound Installation Incorrect SP and SP C Mounted Directly Overhead CSP and SP C Converted to Inline General Maintenance Suggestions Model SP CSP c...

Page 8: ...in the Library under Warranties Greenheck SP and CSP catalog provides additional information describing the equipment fan performance available accessories and specification data Phone 715 359 6171 Fax 715 355 2399 E mail gfcinfo greenheck com Website www greenheck com Our Commitment AMCA Publication 410 96 Safety Practices for Users and Installers of Industrial and Commercial Fans provides additio...

Reviews: