background image

®

Mixed Flow FumeJet

1

®

Document 485229 

Model QEID FJ

Mixed Flow FumeJet

Installation, Operation and Maintenance Manual

Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, 
operate or maintain the product described. Protect yourself and others by observing all safety information. Failure 
to comply with these instructions will result in voiding of the product warranty and may result in personal injury 
and/or property damage.

General Safety Information

Only qualified personnel should install this fan. 
Personnel should have a clear understanding of these 
instructions and should be aware of general safety 
precautions. Improper installation can result in electric 
shock, possible injury due to coming in contact with 
moving parts, as well as other potential hazards. Other 
considerations may be required if high winds or seismic 
activity are present. If more information is needed, 
contact a licensed professional engineer before moving 
forward.
1.  Follow all local electrical and safety codes, as well as 

the National Electrical Code (NEC) and the National 
Fire Protection Agency (NFPA), where applicable. 
Follow the Canadian Electrical Code (CEC) in 
Canada.

2.  The rotation of the wheel is critical. It must be free 

to rotate without striking or rubbing any stationary 
objects.

3.  Motor must be securely and adequately grounded.
4.  Do not spin fan wheel faster than max cataloged fan 

rpm. Adjustments to fan speed significantly effects 
motor load. 

5.  Do not allow the power cable to kink or come in 

contact with oil, grease, hot surfaces or chemicals. 
Replace cord immediately if damaged.

6.  Verify that the power source is compatible with the 

equipment.

7.  Never open access doors to a duct while the fan is 

running.

DANGER

Always disconnect, lock and tag power source before 
installing or servicing. Failure to disconnect power 
source can result in fire, shock or serious injury.

CAUTION

When servicing the fan, motor may be hot enough 
to cause pain or injury. Allow motor to cool before 
servicing.

CAUTION

Precaution should be taken in explosive atmospheres.

DANGER

Pour écarter les risques d’incendie, de choc électrique 
ou de blessure grave, veiller à toujours débrancher, 
verrouiller et étiqueter la source de courant avant 
l’installation ou l’entretien.

ATTENTION

Lors de toute intervention sur la soufflante, le moteur 
peut être suffisamment chaud pour provoquer une 
douleur voire une blessure. Laisser le moteur refroidir 
avant toute maintenance.

ATTENTION

Faire preuve de précaution dans les atmosphères 
explosives.

Summary of Contents for QEID FJ

Page 1: ...an Electrical Code CEC in Canada 2 The rotation of the wheel is critical It must be free to rotate without striking or rubbing any stationary objects 3 Motor must be securely and adequately grounded 4 Do not spin fan wheel faster than max cataloged fan rpm Adjustments to fan speed significantly effects motor load 5 Do not allow the power cable to kink or come in contact with oil grease hot surface...

Page 2: ... packages use a portable electric heater to get rid of any moisture build up The unit should be stored at least 3 1 2 inches 89 mm off the floor on wooden blocks covered with moisture proof paper or polyethylene sheathing Leave coverings loose to permit air circulation and to allow for periodic inspection Aisles between parts and along all walls should be provided to permit air circulation and spa...

Page 3: ...ns that the motor will never operate in the service factor which is possible with many AC motors Installation Instructions Fig 1 Both ends of the strip are bent over 8 10 cm Protect your hands with gloves Fig 2 Hook the ends through the slots in the bracket Fig 3 Hang on threaded rod or ceiling bracket Note 1 The speed control dial is located on junction box Turn dial for speed adjustments to moto...

Page 4: ...per wire is disconnected and capped the motor operates at 208 230 277V see Fig 5 Fig 4 115V Operation Fig 5 208 230 277V Operation Speed Control Dial The speed control dial is mounted on the power pack bracket and is to be plugged into the 9 pin connector on the motor To increase speed rotate the dial clockwise To decrease speed rotate the dial counterclockwise From 0 1 9V the motor will be off an...

Reviews: