DM-45
9
Settings Table
To measure this
characteristic …
Set the
selector to this
symbol …
These icons will
appear on the
display …
Connect
the red
lead to …
Connect
the black
lead to …
DC Voltage (600 V max)
V
and
V
INPUT
COM
AC Voltage (600 V max)
V
and
V
INPUT
COM
Resistance
Ω
MΩ
INPUT
COM
Continuity*
/
and press
and
Ω
INPUT
COM
Diode
and
V
Capacitance**
AUTO
and
nF
INPUT
COM
Frequency
Hz/%
and
press
Hz %
AUTO
and
Hz
INPUT
COM
Duty Cycle
%
Temperature
Temp
°C
or
°F
(press to
change scale)
INPUT
COM
Current (4000 µA max)†
µA
AUTO
µA
,
or
INPUT
COM
Current (400 mA max)†
mA
AUTO
mA
,
or
INPUT
COM
Current (10 A max)†
A
AUTO
A
,
or
10A
COM
* Tone indicates continuity. The threshold is between 20 Ω and 150 Ω.
** Discharge capacitor before measurement. Discharge a large capacitor through an appropriate
resistive load.
† Press
for AC or DC, as required.
Operation
(cont’d)
Summary of Contents for DM-45
Page 10: ...10 Typical Measurements Current Measurement AC Voltage Measurement DC Voltage Measurement ...
Page 12: ...12 Typical Measurements Temperature ...
Page 29: ...DM 45 29 Mediciones más comunes Temperatura ...
Page 36: ...36 ...
Page 47: ...DM 45 47 Mesures types Température ...
Page 54: ...54 ...
Page 63: ...DM 45 63 Typische Messungen Strommessung Wechselspannungsmessung Gleichspannungsmessung ...
Page 64: ...64 Typische Messungen Durchgangsprüfung Kapazitätsmessung Widerstandsmessung ...
Page 65: ...DM 45 65 Typische Messungen Diodenmessung Sperrvorspannung Durchlassspannung Temperatur ...