CSG45GL Cable Cutter
Greenlee Textron / Subsidiary of Textron Inc.
8
4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815/397-7070
Maintenance
Wear eye protection when operating
or servicing this tool.
Failure to wear eye protection can
result in serious eye injury from
flying debris or hydraulic oil.
Skin injection hazard:
Do not use hands to check for oil
leaks. Oil under pressure easily
punctures skin. If injured, seek
medical attention immediately to
remove oil.
Failure to observe this warning can
result in serious injury, gangrene, or
death.
Do not use solvents or flammable
cleaners to clean the tool body.
Solvents could ignite, causing
serious injury or property damage.
Daily
Before use:
1.
Inspect blades for wear or damage, such as cracks,
gouges, or chips.
2.
Inspect the tool for damage or leaks.
After use:
1.
Use a damp cloth and mild detergent to clean the
housing. Allow the housing to dry.
2.
Fully retract the blade. Place the tool in the carrying
case and store in a cool, dry place.
Monthly
1.
Thoroughly clean all surfaces.
2.
Check the oil level.
Annually or After 8000 Cuts
1.
Replace the hydraulic oil.
2.
Send the tool to an authorized Greenlee service
center for inspection.
Checking the Oil Level
1.
Remove the two screws that retain the tank housing
cover. Remove the tank housing cover.
2.
Point the cutting head downward and remove the oil
reservoir plug. Fill reservoir if necessary.
3.
Replace the oil plug and tank housing cover.
Recommended Hydraulic Oils
AVIA
®
HVI 15
Shell Tellus T 15
Mobil
®
DTE 15
NUTO
®
H 15
Keep hands away from closing
blades.