EK06ATL and EK06ATCL Crimping Tools
Greenlee / A Textron Company
4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
9
Problem
Possible Cause
Probable Remedy
Tool is inoperative.
Dirt, contaminants, etc., in ram area
of tool.
Clean tool.
Tool battery contacts damaged.
Reform contacts.
Tool components worn or damaged.
Return tool to a Greenlee Authorized
Service Center.
Motor is inoperative.
Low or uncharged battery.
Try known charged battery. Inoperative
battery may be discharged or may have
reached life expectancy.
Broken switch components.
Return tool to a Greenlee Authorized
Service Center.
Motor runs but tool will not
complete a cycle.
Oil level low.
Return tool to a Greenlee Authorized
Service Center.
Air in hydraulic system.
Pull trigger and hold retract button
simultaneously. Run for approximately
10 seconds, and then attempt to
crimp. If unsuccessful, return tool to a
Greenlee Authorized Service Center.
Cold oil.
Pull trigger and hold retract button
simultaneously to warm oil. Store tool
in warm area.
Dies stop during operation.
Oil level low.
Return tool to a Greenlee Authorized
Service Center.
Air in hydraulic system.
Pull trigger and hold retract button
simultaneously. Hold for approximately
10 seconds.
LED glows for 20 seconds.
Battery charge low.
Charge or replace battery.
Tool loses oil.
Damaged internal seal.
Return tool to a Greenlee Authorized
Service Center.
Note: For Warranty Service or Repair, contact Greenlee customer service at 800-435-0786.
Troubleshooting
Before You Begin
1. Make sure that the battery is charged. Recheck
the battery after several minutes to make sure the
battery is holding its charge.
2. Use a
nonflammable
contact cleaner or pencil
eraser to clean the electrical contacts on the battery
and tool.
3. Reinstall the battery and check the tool again.