Greenlee Textron / Subsidiary of Textron Inc.
10
4455 Boeing Dr., Rockford, IL 61109-2988 815/397-7070
GATOR
TM
ES1000 Battery-Powered Cutter
BEFORE YOU BEGIN
1.
Make sure that the battery is charged. Recheck the
battery after several minutes to make sure the
battery is holding its charge.
Troubleshooting
PROBLEM
PROBABLE CAUSE
POSSIBLE REMEDY
Tool doesn’t operate.
Crimper battery contacts are bent.
Reform contacts.
Dirt or other contaminants in the
Clean tool.
cutting head of the tool.
Blade stops before operation
Oil level is low.
Check oil level. Fill reservoir if
is complete.
necessary.
Air in hydraulic system.
Pull trigger and hold release lever
simultaneously. Hold for approximately
10 seconds.
Exceeded capacity of cutter.
Use alternate cutting method.
LED flashes constantly.
Battery charge is low.
Recharge battery.
Low battery life.
Battery is exhausted.
Replace battery.
Service
Should your battery-powered cable cutter require service, return it to an authorized Greenlee service center.
Customer Center and Field Service: 800/435-0786
Fax (24 Hour) Customer Center: 800/451-2632 or 815/397-1865
2.
Use a NONFLAMMABLE contact cleaner or pencil
eraser to clean the electrical contacts on the battery
and cable cutter.
3.
Reinstall battery and check the tool again.