ES1000 Battery-Powered Cutter
Each Operating Day
Before Use:
Inspect blades for damage, such as cracks, gouges or
chips. If blade is damaged, replace before using cutter.
Maintenance
Monthly
1.
Thoroughly clean all surfaces.
2.
Check the oil level.
3.
Oil the bolt joints.
4.
Lubricate blades with a Teflon or WD40-type
lubricant.
Annually
1.
Change the hydraulic oil
2.
Return the tool to an authorized Greenlee service
center for inspection.
General
The hydraulic oil needs to be changed annually or every
8000 cuts.
Store the cable cutter in the carrying case when it is not
in use.
Checking the Oil Level
1.
Remove the two screws holding the tank housing
cover.
2.
Remove the tank housing cover.
3.
Point the cutting head towards the ground and
remove the oil plug. Refill reservoir if necessary.
4.
Replace the oil plug and the tank housing cover.
Recommended Hydraulic Oils
AVIA HVI 15
Shell Tellus T 15
MOBIL DTE 11
NUTO H 15
• Keep hands and fingers away
from closing blades.
• Lock trigger when not in use.
Skin Injection Hazard:
Do not use hands to check for oil
leaks. Oil under pressure easily
punctures skin; if injured, seek
medical attention immediately to
remove oil.
Failure to observe this warning
can result in serious injury, gan-
grene or death.
After Use:
1.
Clean all exposed surfaces with a slightly damp
cloth and a mild detergent. Dry all exposed
surfaces.
2.
Clean out metal chips from around the blades.
3.
Check the charge level of the battery. Charge if
necessary. See the battery charger instructions.
4.
Fully retract and lock the blades. Place the cable
cutter in the carrying case and store in a cool, dry
place.
Do not use solvents or flammable
cleaners to clean the cutter.
Solvents could ignite and cause
serious injury or death.