Troubleshooting

Before You Begin

1.  Make sure that the battery is charged. Recheck 

the battery after several minutes to make sure the 

battery is holding its charge.

2.  Use a 

nonflammable

 contact cleaner or pencil 

eraser to clean the electrical contacts on the battery 

and tool.

3.  Reinstall the battery and check the tool again.

Problem

Possible Cause

Probable Remedy

Tool is inoperative.

Battery charge low.

Charge or replace battery.

Dirt, contaminants, etc., in 

ram area of tool.

Clean tool.

Tool components worn or 

damaged.

Contact Greenlee customer service at  

800-435-0786 for warranty service or repair.

Motor is inoperative.

Low or uncharged battery.

Try known charged battery. Inoperative battery may 

be discharged or may have reached life expectancy.

Broken switch components.

Contact Greenlee customer service at  

800-435-0786 for warranty service or repair.

Motor runs but tool will not 

complete a cycle.

Oil level low.

Contact Greenlee customer service at  

800-435-0786 for warranty service or repair.

Air in hydraulic system.

Pull trigger and hold retract button simultane-

ously. Run for approximately 10 seconds, and then 

attempt to cut. If unsuccessful, contact Greenlee 

customer service at 800-435-0786 for warranty 

service or repair.

Cold oil.

Pull trigger and hold retract button simultaneously 

to warm oil. Store tool in warm area.

Tool loses oil.

Damaged seal.

Contact Greenlee customer service at  

800-435-0786 for warranty service or repair.

Summary of Contents for GATOR ESC105LX

Page 1: ...on Inc 3 17 Serial Number Read and understand all of the instructions and safety information in this manual before operating or servicing this tool Register this product at www greenlee com ESG55LX sh...

Page 2: ...nnel Replacement manuals are available upon request at no charge at www greenlee com Do not discard this product or throw away For recycling information go to www greenlee com KEEP THIS MANUAL Table o...

Page 3: ...rotective equipment Failure to observe this warning could result in severe injury or death Electric shock hazard The owner of this cutter must be certain that all users of this tool are trained in the...

Page 4: ...tions may result in injury or property damage Do not allow anything to contact the battery terminals Do not immerse the batteries in liquid Liquid may create a short circuit and damage the battery If...

Page 5: ...ESG105LX Locking Flange ESG50LX Handle removable ESG55LX ESC85LX ESC105LX and ESG105LX 2 Blades 3 Lanyard Ring 4 Housing 5 Retract Button 6 LED Indicator red 7 LED Work Light white 8 LCD Screen 9 Bat...

Page 6: ...g Diameter copper and aluminum 2 12 55 mm ACSR Joree 76 19 2515 kcmil Guy Strand 5 8 16 mm dia EHS Guy Strand 9 16 14 mm dia 3 4 Ground Rod 3 4 19 mm dia Rebar Schedule 60 5 8 16 mm dia Soft Steel Bol...

Page 7: ...ol for 15 minutes Do not secure this tool in a vise This tool is designed for hand held operation This tool may be used in damp or wet environ ments however air drying is recommended before use if the...

Page 8: ...cutting head and insert pull pin 4 Pull the trigger The blades will begin to close 5 When the cut is completed the ram will retract completely 6 To stop the ram from returning fully activate the trigg...

Page 9: ...ttery empty tool won t run 10 Real time clock battery low 11 Tool deactivated 12 Service necessary 13 Real time clock not found 14 Bluetooth unit not found 15 16 Pressure sensor not found 17 Burst pre...

Page 10: ...ay from the cutting head when cutting Failure to observe these warnings could result in severe injury or death Relief valve adjustments must be done by an authorized service center Daily Before use 1...

Page 11: ...800 435 0786 for warranty service or repair Motor is inoperative Low or uncharged battery Try known charged battery Inoperative battery may be discharged or may have reached life expectancy Broken sw...

Page 12: ...8 USA 815 397 7070 An ISO 9001 Company Greenlee Textron Inc is a subsidiary of Textron Inc USA Tel 800 435 0786 Fax 800 451 2632 Canada Tel 800 435 0786 Fax 800 524 2853 International Tel 1 815 397 70...

Reviews: