Greenlee Textron / Subsidiary of Textron Inc.
8
4455 Boeing Dr., Rockford, IL 61109-2988 815/397-7070
ESG45GL Battery-powered Cable Cutter
Troubleshooting
Problem
Probable Cause
Probable Remedy
Tool is inoperative.
Dirt, contaminants, etc., in ram area
Clean tool.
of tool.
Crimper battery contacts damaged.
Reform contacts.
Tool components worn or
Return tool to an authorized
damaged.
Greenlee service center.
Cutting blades stop during
Oil level is low.
Check oil level. Refill reservoir.
operation.
Air in hydraulic system.
Pull trigger and hold retract button
simultaneously. Hold for approximately
10 seconds.
Battery load display flashes
Battery charge low.
Charge or replace battery.
constantly.
Tool loses oil.
Damaged internal seal.
Return tool to an authorized Greenlee
service center.
Oil plug not installed properly.
Refill reservoir and replace plug.
Before You Begin
1.
Make sure that the battery is charged. Recheck
the battery after several minutes to make sure the
battery is holding its charge.
2.
Use a nonflammable contact cleaner or pencil
eraser to clean the electrical contacts on the battery
and cable cutter.
3.
Reinstall battery and check the tool again.
Service
Should your battery-powered cable cutter require service, return it to an authorized Greenlee service center.
Customer Center and Field Service: 800/435-0786
Fax (24 Hour) Customer Center: 800/451-2632 or 815/397-1865