Maintenance
Each Operating Day
Before use:
1. Inspect blades for damage such as cracks, gouges,
or chips.
2. Inspect the tool for damage or leaks. Return a
damaged or leaking tool to an authorized Greenlee
service center.
Skin injection hazard:
Do not use hands to check for oil
leaks. High pressure oil easily punc-
tures skin causing serious injury,
gangrene, or death. If injured, seek
medical help immediately to remove
oil.
After use:
1. Wipe all tool surfaces clean with a damp cloth and
mild detergent.
Do not use solvents or flammable
liquids to clean the tool body.
Solvents or flammable liquids could
ignite and cause serious injury or
property damage.
2. Fully retract the blades. Place the tool in the carry
-
ing case. Store in a cool, dry place.
3. Charge the battery.
Monthly
1. Thoroughly clean all surfaces.
2. Check the oil level.
3. Oil the bolt joints.
Annually or Every 8000 Cutting Cycles
1. Change the hydraulic oil.
2. Return the tool to an authorized Greenlee service
center for inspection.
Cutting hazard:
•
Remove battery before changing
dies, adapters, or jaws.
• Keep hands away from the cutting
head when cutting.
Failure to observe these warnings
could result in severe injury or death.
Checking the Oil Level
1. Remove the two screws that retain the tank housing
cover.
2. Remove the tank housing cover.
3. Point the head downward and remove the oil plug.
Add oil if necessary.
4. Replace the oil plug and the tank housing cover.
Secure with screws.
Recommended Hydraulic Oils
AVIA
®
HVI 15
Shell Tellus T 15
Mobil
®
DTE 11M
NUTO
®
H 15