13
GT-65 • GT-95
Specifications and Accuracy
(cont’d)
Continuity Test: 0 to 50 k
Ω
Test Current (typical): 0.7
µ
A
Open Circuit Voltage: Less than 2.0 VDC
Indication: Tone and LED
GFCI Test (for 120 V nominal circuits only—GFCI test is disabled
above 132 V and below 80 V):
Test Current: 7.5 mA nominal at 120 V
Impedance: 16 k
Ω
nominal
Internal Load: 0.9 W @ 120 V
Operating/Storage Conditions: –10
°
C to 50
°
C (14
°
F to 122
°
F)
0% to 85% relative humidity
Altitude: 2000 m (6500') maximum
Pollution Degree: 2
Indoor use only
Remove batteries before storing.
Battery: Two 1.5 V batteries (AAA, NEDA 24A or IEC LR03)
Measurement Categories: CAT IV, 600 V / CAT III, 1000 V per UL 61010
GT-95 Only
Display: 3-digit LCD (999 maximum count)
Display Turn-on Voltage: 15 VAC, 5 VDC (nominal)
Voltage Resolution: 1 V (AC or DC)
LCD Accuracy:
ACV:
±
(2.5% of r 4 V)
DCV:
±
(1% of r 2 V)