10
Operation (cont’d)
Test Table
LED Table
LED Illuminated
Indication
LED 1
Positive (+) DC of 4.5 V or more
LED 2
Negative (–) DC of 4.5 V or more
LED 3
AC of 8 V or more
LED 4 only
Continuity present
Other voltage LEDs
Approximate voltage level
LED 1
LED 2
LED 4
LED 3
To test/verify
Connect the
Connect the
The tester
this value:
red lead to:
black lead to:
will indicate:
Continuity
Component
Component
Tone for resistance
or circuit
or circuit
of 0 to 50 k
Ω
under test
under test
(approximately)
AC voltage
Component
Component
Voltage of 8 V
or circuit
or circuit
or greater*
under test
under test
DC voltage
Component
Component
Voltage of 4.5 V
or circuit
or circuit
or greater,
under test
under test
plus polarity*
RCD
Hot or live
Earth
Refer to “Typical
(GT-95e only)
conductor
ground
Measurements”
for complete
testing instructions.
* GT-95e also displays voltage on LCD.