Problem
Probable Cause
Possible Remedy
Motor will not run.
No power at supply circuit.
Check power supply with a voltmeter.
See the Specifications section of this manual.
Faulty switch or wiring.
Check the switch and wiring for continuity.
Motor faulty.
Check the motor and wiring for continuity.
Check condition of brushes. Replace any worn or
damaged items.
Replace motor.
Capstan does not rotate
while motor is running.
#60 chain broken.
Replace #60 chain.
#40 chain broken.
Replace #40 chain.
Broken sprocket in gearbox or
stripped shaft in motor.
Disassemble puller. See disassembly instructions
under Inspecting the Chains and Ratchet Pawl.
Replace any worn or damaged drive components.