field of application
Hybrid managers are used for different types of process water (e.g. rainwater and treated
greywater from various underground tanks) are transferred from different tanks to a central
location for storage and then they are pumped with a booster station to the service water
supply system in buildings.
They may be also necessary when the suction section of the pressure/suction pumps has
adverse geotechnical conditions, or is too long. High operational reliability is ensured by solid
floating switches in the hybrid tank and integrated mains water back-up.
notes and explanations
If the system is not used for a long time, unplug the power plug from the live socket and
close the drinking water line.
•
the system must be operated via a FI circuit breaker
•
moisture compartment sockets must be installed above the GHM for connection and
commissioning
•
check the system regularly for leakages on all components
•
the GHM should be installed only in roosm with a floor drain
•
in frost-prone areas the operation is prohibited
•
the installation in wet rooms – like bathrooms – is prohibited
•
the conductor may not be placed in the ground without protection (empty pipe, KG
pipe
•
to disconnect from the mains - unplug the mains plug (should be never covered)