Troubleshooting:
1. Unit fails to turn on.
Hose or power connection problem.
Check the power cables for secure connection and make sure the hoses to your
pureWash are connected to the correct inlet/outlet.
2. Alarm sounding.
Condensation or a leak has pooled water along the bottom of the pureWash.
Remove the Power Cord and cover of your pureWash. Clean any standing water and
dry the sensor on the bottom panel with alcohol. If the problem persists contact your
distributor or GreenTech Environmental.
3. Flashing red light.
Oxidizing Module has failed.
Contact your distributor or GreenTech Environmental for replacement.
4. No ozone smell in laundry.
Check the viewing glass for bubbles
as it may be producing ozone but not injecting it
into the water correctly. If bubbles are present, the Oxidizing Module may have failed.
Contact your distributor or GreenTech Environmental for replacement.
5. No bubbles are being created.
Incorrect pressure before/after Venturi or Venturi is plugged.
First check for obstruction between the pureWash and the washer (inlet screen to
washer). Ensure house pressure at the supply valve has minimum of 40psi. If this
fails to correct the problem then backflush your unit by switching the hoses on the
pureWash inlet/outlet and place the inlet hose into the basin or bucket to drain to
clear the Venturi. Then return hoses to proper connections.