Requirements according ISO 9869-1:2014
4.1
Always use the supplied double-sided adhesive tapes to mount the sensor since it has been calibrated for it.
Inside and outside sensors must be mounted exactly opposite to each other at the same wall for good
results.
Use the supplied sensor clips to mount the sensor.
Avoid direct solar radiation onto the sensor.
Place the sensor between 5-10cm next to the heat flux or surface temperature sensor.
The duration of the measurement should be at least 72h.
A temperature difference between inside and outside temperature of at least 5°C during the entire period
is recommended.
If surrounding conditions are strongly fluctuating it might take longer than 72h to assess an ISO 9869
compliant U-value. In this case a multitude of 24h is recommended on top of the 72h time period.
Mounting of the surface temperature sensor and the (combined) surface temperature/heat flux sensor
Mounting of the ambient temperature sensor
General
DISCLAIMER:
The above restrictions, recommendations, materials, etc. do not cover all possible
cases and items. This document is not to be considered complete and is subject to change
without prior notice. In particular, greenTEG assumes no liability for damages caused by the
installation/de-installation of the system to/from the wall.
Charging of the Measurement System
With the supplied power supply, it takes approximately 5 hours to charge the Base Station, however we
recommend it not to be unplugged as battery life is only 48 hours.
The node battery lasts approximately 2 years and can be replaced once empty.
For additional chargers and batteries visit our e-shop or contact us.
19
Summary of Contents for GO MEASUREMENT SYSTEM II
Page 1: ...gOMS II greenTEG GO MEASUREMENT SYSTEM II USER MANUAL...
Page 2: ...CONTENTS I 01 02 03 04 OVERVIEW SET UP ANALYSING MEASUREMENTS APPENDIX...
Page 9: ...01 02 03 04 OVERVIEW SET UP ANALYSING MEASUREMENTS APPENDIX CONTENTS 7...
Page 13: ...CONTENTS 12 01 02 03 04 OVERVIEW SET UP ANALYSING MEASUREMENTS APPENDIX...
Page 18: ...CONTENTS 17 01 02 03 04 OVERVIEW SET UP ANALYSING MEASUREMENTS APPENDIX...
Page 22: ...Appendix C Detailed explanations of the parameters used in the report 4 3 21...