LOCATION
The HRV must be located in a conditioned area where it will be possible to conveniently service the unit. The HRV would be located in the mechanical
room, above a drop ceiling or an area close to the outside wall where the weatherhoods will be mounted. Attic installations are not normally
recommended due to extreme temperatures variation, and difficulty in performing required service & maintenance. If an attic is selected, special care
should be taken in ensuring the unit will perform as intended. Unit may need to be protected with insulated shelter, built on site.
Connecting appliances to the HRV
It is not recommended, including:
• clothes dryer
• kitchen exhaust hoods
• combustion venting
• central vacuum system
These appliances may cause lint, dust or grease to collect in the HRV , damaging the unit or risk of hazard.
Connecting any of these type of appliances to the HRV will void warranty
LCH-H series has dual has access doors on the front and back. Also, the main electrical control panel may be moved from front to back allowing for
ducting layout.
OUTDOOR AIR CONNECTIONS
(COLD SIDE)
OUTDOOR AIR CONNECTIONS
(COLD SIDE)
INDOOR AIR CONNECTIONS
(WARM SIDE)
INDOOR AIR CONNECTIONS
(WARM SIDE)
Default Configuration. Unit may be easily reversed in field.
1. INSTALLATION
2. OPTIONAL REVERSIBLE APPLICATION
LCH-4H, LCH-7H, LCH-12H