4. Mounting Unit 

The unit can be mounted to a wall surface. There are two ways to position the unit: vertically 
and horizontally.   
1. Use a ruler to draw a straight line in 114 mm vertically or horizontally on the wall.   
2. Use a sharp nail to puncture the center of the two ends to mark the wall. 
        (see below chart 1 as placing the unit horizontally) 
3. Mount the unit by positioning the key-hole slots over the mounting nails. (see chart 2 and 
chart 3) 

Chart 1 

Chart 2   

Chart 3 

114 mm distance between 2 holes   

Mounting horizontally   

Mounting vertically 

 

 

 

 

5. Applications 

CAUTION: 

The total power consumption of all equipment plugged into the voltage 

regulator must not exceed its capacity*. A total load in excess of its capacity* will cause the 
fuse to fault (blow). 
*For the capacity of unit, please check the specifications. 
 
The voltage regulator is designed for use with voltage sensitive equipment such as: a home 
computer, monitor, inkjet printer, scanner or fax. It is also designed for use with home 
electronics equipment such as television, stereos, CD players, VCRs, and DVD players, data 
processing equipment, modems, typewriters, calculators, and telephone equipment. 
 
Appliances not suitable for use with the product are items such as freezers, power tools, air 
conditioners, dehumidifiers, blenders, or any device that employs an AC motor for operation. 
Not for use with small fuel generators. Also excluded are life sustaining equipment. 
 
When use the voltage regulator with an Uninterruptible Power Supply (UPS), connect the 
UPS to the output of this product, then connect the product to the wall outlet. 

6. Important Safety Warning (SAVE THESE INSTRUCTIONS) 
 

To safely operate this voltage regulator, please read and follow all instructions 
carefully. Read this manual thoroughly before attempting to unpack, install, or 
operate. You may keep this quick guide for further reference. 

 

CAUTION: 

The unit is designed only for use under the 50 Hz input frequency and pure sine 

wave environment. Any other input frequency or wave form will effect the voltage range 
and load capability. 

 

CAUTION: 

Please DO NOT connect the unit to the environment with direct voltage or 

simulated sine wave. 

 

CAUTION! 

To prevent the risk of fire or electric shock, install in a temperature and 

humidity controlled indoor area free of conductive contaminants. (See the specifications for 
the acceptable temperature and humidity range.) 

 

7 Specifications 

Model 

600 

1000 

1500 

CAPACITY 

600VA/300W 

1000VA/500W 

1500VA/750W 

INPUT

 

Voltage 

230 VAC 

Voltage Range 

184-284 VAC 

Frequency 

50 Hz 

OUTPUT

 

Voltage Regulation 

±  10% 

Output Receptacles 

Schuko x 3 / Universal x 3 / India x 3 

INDICATOR

 

Power LED 

Green lighting 

AVR LED 

Yellow lighting 

Over-voltage LED 
(option) 

Red lighting 

PHYSICAL

 

Dimension (DxWxH) 

180 x 95 x 114 mm 

Net Weight (kgs) 

1.36 

1.6 

1.96 

Environment

 

Humidity 

0-90 % RH @ 0-40° C (non-condensing) 

Noise Level 

Less than 40 dB 

 

Reviews: