TROUBLE SHOOTING
DANGER
Prior to all servicing:
Switch machine off. Disconnect the mains plug. Wait
until the device has stopped. Ensure that there is no
more pressure on the device and all used compressed
air tools and accessories.
Leave the device and all used compressed air tools
and accessories to cool down.
Any works other than the ones described in this
chapter, must be carried out only by a qualified
electrician or the service branch in your country.
After all servicing:
Put back into operation and check all safety installations.
Ensure that there are no tools or similar at or in the device.
Compressor does not run:
• No mains voltage.
–
Check cables, plug, outlet and mains fuse.
• Mains voltage too low.
–
Use only extension cables with sufficient lead cross-
section. For cold device: Avoid extension cable. For cold
device: Depressurise the pressure vessel.
•
Compressor was switched off by pulling the mains plug
while it was running.
–
First, switch off the compressor using the ON/ OFF
switch (9), then switch on again.
•
Motor overheated, e.g. due to insufficient cooling
(cooling ribs covered).
–
Switch off the compressor using the ON/OFF switch (9) .
–
Remedy the cause for overheating. Leave to cool
for about ten minutes.
–
Switch on the compressor again using the ON/ OFF
switch (9) .
Compressor runs without building up sufficient
pressure.
•
Condensate outlet leaking.
–
Ensure that the condensate outlet (3) is closed.
–
Check the seal of the drainage plug, if required,
replace.
•
Check valve leaking.
–
Have check valve serviced in authorised service
centre.
Compressed air tool does not get enough pressure.
• Pressure controller not open enough.
–
Open pressure controller (7) further.
• Hose connection between compressor and compressed
air tool leaking.
–
Check hose connection; if required replace
damaged parts.
TECHNICAL SPECIFICATIONS
Input
220 l/min
Output
120 l/min
Max. working pressure
8 bar
Pressure vessel volume
24 L
No. of air outlets
1
No. of cylinders
1
Motor speed
2850 min-1
Motor capacity
1.5 kW
Supply voltage (50 Hz)
230 V
Rated current
6.0 A
Degree of protection
IP 20
Max. overall cable length when
using extension cables:
– at 3 x 1.0 mm2 lead cross section 10 m
– at 3 x 1.5 mm2 lead cross section
25 m
– at 3 x 2.5 mm2 lead cross section
25 m
Weight
24 kg
Sound pressure level
97 dB (A)