Link-Belt MG-534 Calibration
9
W450160 10/07
group “B” fault Codes
Group “B” fault codes represent faults detected for internal analog functions and power feeds to the
function kickout and anti-two block switches.
Fault
Code
FKO
Power
Feed
ATB
Power
Feed
Display
Console
ADC 2
Internal
Fault
ADC 1
Internal
Fault
Action
000
No Fault Found
None
001
X
Replace computer.
002
X
003
X
X
004
X
005
X
X
006
X
X
007
X
X
X
008
X
Refer to “Anti-Two-Block Function on
page 41 of the Troubleshooting manual
(W450161).
009
X
X
Replace computer.
010
X
X
011
X
X
X
012
X
X
013
X
X
X
014
X
X
X
015
X
X
X
X
016
X
Check crane circuit breakers. Then, re-
fer to “Function Kickout Fuse (FS2) on
page 19 of the Troubleshooting manual
(W450161).
017
X
X
Replace computer.
018
X
X
019
X
X
X
020
X
X
021
X
X
X
022
X
X
X
023
X
X
X
X
024
X
X
Check crane circuit breakers. Then, re-
fer to “Function Kickout Fuse (FS2) on
page 19 of the Troubleshooting manual
(W450161).