Link-Belt MG-534 Calibration
11
W450160 10/07
Fault
Code
Serial
EEPROM
Crane
Data
RAM
Duty Data Program
Action
024
X
X
Reselect crane setup/configuration.
Reset crane data. Otherwise, replace
computer if not resolved.
025
X
X
X
Reselect crane setup/configuration.
Otherwise, replace computer if not
resolved.
026
X
X
X
027
X
X
X
X
028
X
X
X
Replace computer.
029
X
X
X
X
030
X
X
X
X
031
X
X
X
X
X
group “D” fault Codes
Group “D” fault codes represent faults detected for capacity chart selection.
Fault
Code
Wrong
Swing
Area
Wrong
Boom
Length
Chart Not
Found
Action
000
No Fault Found
None
001
X
Check other sensor faults. Reselect crane setup.
002
X
Boom length is out of range for selected chart. Check crane
setup, boom length, and boom extension.
003
X
X
Check other sensor faults. Reselect crane setup.
004
X
Swing to correct working area to select chart. Check swing sen-
sor zero position, refer to “Swing Sensor Setup and Checks” on
page 46 of the Troubleshooting manual (W450161).
005
X
X
Swing to correct working area to select chart. Check swing sen-
sor zero position, refer to “Swing Sensor Setup and Checks” on
page 46 of the Troubleshooting manual (W450161).
006
X
X
Check other sensor faults. Reselect crane setup.
007
X
X
X
Check other sensor faults. Reselect crane setup.
Summary of Contents for MG-534