Link-Belt MG-534 Calibration
18
W450160 10/07
Press the key adjacent to
Yes! Calibrate!
to perform the
calibration, otherwise press the key adjacent to
No, Exit/
Abort
to cancel.
Boom Extension Sensor
m
WARNINg
DO NOT fuLLy ExTEND ThE BOOM If ThIS ACTION COuLD CAuSE A TIPPINg CONDITION.
CARRy OuT CALIBRATION PROCEDuRES ONLy WIThIN ThE STABILITy LIMITS Of ThE CRANE.
T
S
With the boom still fully retracted, lower it to a horizontal position. Measure the distance from the
boom pivot to the hook centerline (S).
Next, fully extend the boom and measure the distance from the boom pivot to the hook centerline (T).
Calculate the span by subracting the fully retracted length from the fully extended length
(T - S = span).
1
With the boom still fully extended, calibrate the span of the extension following the steps below.
Press the key adjacent to
Menu Down
to go to Span No. 2.
Press the key adjacent to
Span No. 2 X.XX
(where X.XX =
actual input).
1 An optional method for calculating the span is to refer to the crane load chart which will show the fully retracted boom length and
the full extended boom length.
LOAD
0.8
ANGLE
41.8
RADIUS
76.2 FT
LENGTH
106.0
Span Sensor
YES! Calibrate!
NO, Exit / Abort
Exit
Exit
LOAD
0.8
ANGLE
41.8
RADIUS
76.2 FT
LENGTH
106.0
Span Sensor
Span No.2 0.00
Menu Up
Menu Down
Exit