User manual GRENTON RELAY X2+ WiFi
WRE-222-W-01

Grenton RELAY X2+ WiFi allows you to control
up to two outputs (max. 350VA), two digi-
tal inputs (230 Vac). The X2+ version pro-
vides current and power measurements each
output channel. It contains the Common Logic
Unit (CLU) with WiFi wireless communication
controller, executes the function of process-
ing logic and storing the configuration.

1. Technical data

Device power supply

110-230 Vac 50/60 Hz

Maximum power consumption

1,8 W

Rated load voltage

230 Vac or 24 Vdc

Rated channel load AC1

1,5 A / 230 Vac / per chan-
nel

Rated channel load DC1

1 A / 24 Vdc / per channel

Maximal breaking capacity AC1

350 VA / per channel

Maximum wire cross section

2,5 mm2

WiFi frequency band

2,4 GHz

Weight

40 g

Fixing

flush mounted

Dimensions (H/W/D)

19/45/36 mm

Operating temperature range

0 to +45 °C

2. Wiring diagram

The device without a tar-

get configuration loaded via
Object Manager tool, has
the minimal embedded con-
figuration. The inputs are
connected to the outputs,
which allows for local loads
control.

N

”Neutral” signal

L

”Line” signal

AC IN1

first channel input (230 Vac)

AC IN2

second channel input (230 Vac)

REL1

first channel output (potential free)

COM

common output for REL1 and REL2

REL2

second channel output (potential free)

3. Wireless communication configuration

The brand new device on power

up starts with the AP (access point) SSID:
CLU36xxxxxxx [reset] with the factory pass-
word (PIN) ”00000000”. After connection
setup with the AP please connect to the
device http server using web browser and
http://192.168.4.1 link. Next please set up a
PIN and a WiFi network parameters, the WiFi
network the device is meant to be connected
to. The PIN is the new AP password and the

”Secret Key” used by the Object Manager tool
during the discovery process as well. In case of
connection failure with the previously configu-
rated WiFi network Relay X2+ WiFi starts with
the AP SSID: CLU36xxxxxxx after 2 minutes
of unsuccessful retries. After 10 minutes from
the power on the AP is deactivated and the
Relay X2+ WiFi only keeps trying to connect to
the configurated WiFi network.

4. Restoring Factory Settings

Restoring Factory Settings activates

sequence of 5 pulses ended with 2 seconds
break given to one of the inputs. Duration of the

5 pulses must be less than 5 seconds. The time
window while the factory reset can be done is
from 5 to 30 seconds from the power on.

5. Warnings and cautionary statements

ATTENTION !

Before proceeding with the assembly, read

the installation schematics and full instructions
available at www.grenton.com. Failure to follow
the guidelines contained in the instructions and
other requirements of due care valid as a result
of the nature of the equipment (device) may be
dangerous to life / health, damage the device
or installation to which it is connected, damage
other property or violate other applicable regu-
lations. The manufacturer of the device, Gren-
ton Sp. z o. o. does not bear any responsibility

for the damage (property and non-property re-
lated) resulting from the assembly and / or use
of the equipment not in accordance with the in-
structions and / or due diligence in handling the
equipment (device).

Device power supply, permissible load or

other characteristic parameters have to be in
accordance with the device specification, de-
scribed in particular in the ”Technical data” sec-
tion.

The product is not intended for children and

animals.

If you have technical questions or comments

about the device operation, contact Grenton
Technical Support.

Answers to frequently asked questions can

be found at: www.support.grenton.pl

DANGER !

Danger to life caused by electric current!

The components of the installation (individ-

ual devices) are designed to work in a home

electrical installation or directly in its vicinity. In-
correct connection or use may cause a fire or
electric shock.

All work related to the installation of the de-

vice, in particular works involving interference
in the electrical installation, may be performed
only by a person with appropriate qualifications
or licences.

When installing the device, make sure that

the power supply voltage is disconnected from
the circuit in which the device is connected or
near which the assembly takes place.

6. CE marking

The manufacturer declares that the de-

vice is in full compliance with the requirements
of EU legislation that includes the directives of
a new approach appropriate for this equipment.
In particular, Grenton Sp. z o. o. declares that
the device fulfills the requirements on safety,
specified by law, and that it conforms to the

national regulations that implement the appro-
priate directives: The Radio Equipment Direc-
tive (RED - 2014/53/UE), the Low Voltage Di-
rective (LVD 2014/35/UE) and the Directive on
the limitation of the use of specific substances
in electrical and electronic equipment (RoHS II -
2011/65/UE).

7. Warranty

Warranty available at: www.grenton.com/warranty