Page 38
DLT 2.0 Differential Level Transmitter
SPECIFICATIONS
Accuracy:
0.25%
F.S.,
Repeatability: 0.1%
F.S., Linearity:
0.1%F.S.
Displays:
White, backlit matrix -
displays flow rate,
totalizer, relay states,
operating mode and
calibration menu
Calibration:
built-in 5-key calibrator
with English, French or
Spanish language
selection
Power Input:
100-240VAC, 50/60Hz, 30 Watts or
9-32VDC, 9 Watts max
Output:
Isolated 4-20mA (1000 ohm load max.)
Control Relays:
Qty 2, rated 5 amp 240VAC SPDT, programmable flow alarm and/or
proportional pulse
Enclosure:
watertight, dust tight NEMA4X (IP 66) polycarbonate with a clear
shatter-proof face
Environmental Conditions:
Relative humidity up to 80% -23 to 60°C ambient temperature,
maximum 5000 m altitude, pollution degree 4, Installation Category II.
Sensitivity:
adjustable. Damping: adjustable
Electrical Surge Protection:
Sensor, 4-20mA output and AC power input
Approximate
Shipping Weight:
10 lbs (4.5 kg)
Standard Sensor PZ15
Maximum Range:
15 ft (4.57 m)
Minimum Range (Deadband):
8" (203.2 mm)
Operating Frequency:
92
KHz
Beam Angle:
8°
Operating Temperature:
-40° to 150° (-40° to
65°C)
Temperature Compensation:
Automatic,
continuous
Max. Operating Pressure:
20 psi (1.35 bar)
Sensor Face:
PVC
Sensor Body:
PVC
Mounting:
¾"
NPT
Cable Length:
25 ft. (7.6 m) continuous
RG62AU coaxial.
Optional 50 ft. (15 m)
continuous
Max. Cable Length:
500 ft. (152 m) RG62AU
coaxial (splice)
Hazardous Rating:
CSA rated Intrinsically
Safe Class I, Groups
C,D, Class II, Groups E,F,G with Optional Intrinsic Safety Barrier.
7.4 / 188 mm
"
6.46 / 164 mm
"
10.94"
/278
mm
10
/254
mm
"
CONDUIT ENTRY
LOCATION
SIDE VIEW
5.12 / 130 mm
"
DLT 2.0
Differential Level
Transmitter
2
5 ft
(
7
.6
m
)
RG
62
AU
COAX
I
AL CABLE
(
5
0
ft
1
5 m OR
100
ft
30
m
)
OPT
I
ONAL
3
/
4“
NPT
I
SOLAT
I
ON
COUPL
I
NG
(
SUPPL
I
ED
)
3
/
4"
NPT
1.12
5
"
(2
8
.6
mm
)
~4.2
5
"
(10
8 mm
)
O
V
ERALL
3.12
5
"
7
9.4
mm
2.1" (
5
3
mm
)