30
6.9.5 RJ45 Connection
RJ45 is specifically employed here for LAN/WLAN via which inverter web page
can be easily accessed. Refer to figures below and on P.25 for RJ45 wiring. Make
sure that RJ45 cable is wound through the brown EMI core (from accessary kit)
with 4 turns each, as for noise immunity
6.9.6 Connecting GFCI Buzzer (Optional)
Buzzer is used to alert user when ground fault current interrupter (GFCI) is
active. It’s also known as residual current monitoring unit (RCMU).
1.
Insert extension cord through the M20 cable gland and connect to
designated socket on inverter, as illustrated below and on P.25
2.
Attach and fix the buzzer on an
indoor
surface such as a wall
3.
Connect buzzer with extension cord
4.
If the length of cord is not enough, please trim and extend with some
similar cord to desired length
PV-5000T-U/PV-8000T-U/PV-10000T-U
PV-15000T-U/PV-20000T-U
Place the Buzzer Where You Can Hear
The buzzer will notice you in case of ground current fault.
Place it near you. Do not put in a cabinet or place far away.
Extension Cord for Buzzer
RJ45 Cable for Internet
Extension Cord for Buzzer
RJ45 Cable for Internet
Summary of Contents for PV-10000T-U
Page 12: ...11 5 4 Product Labels ...
Page 14: ...13 6 2 Unpacking PV 15000T U ...
Page 15: ...14 6 3 1 Unpacking PV 20000T U ...
Page 16: ...15 6 3 2 Unpacking PV 20000T U E Display ...
Page 17: ...16 6 4 Assembly Chart PV 5000T U PV 8000T U PV 10000T U PV PV15000T U ...
Page 18: ...17 6 5 Assembly Chart PV 20000T U ...
Page 81: ...80 14 Addendum 14 1 Efficiency Charts 14 1 1 PV 5000T U 14 1 2 PV 8000T U ...
Page 82: ...81 14 1 3 PV 10000T U 14 1 4 PV 15000T U ...
Page 83: ...82 14 1 5 PV 20000T U ...
Page 84: ...P N MUB0 A00000 0 ...