33
6.9.10 Unplugging PV
In case you need to disconnect the PV,
follow the steps below.
a.
SWITCH OFF PV!
b.
Use preferred Wieland
assembling/disconnecting
mounting tool PST (Art. No.
05.502.1753.0
)
c.
Push interlock to release plugs
d.
Pull off plugs
Danger of Electric Shock!
While working on DC wiring, make sure DC is completely
turned off.
Polarity & Voltage Check
Before plugging in, make sure all polarities and voltages are
correct. Incorrect connections could cause malfunction.
Multiple PV Connections for PV-8000T-U/PV-10000T-U/PV-15000T-U/
PV-20000T-U
Either two paralleled DC feeds from one common PV string
or two independent DC strings can be set up for PV-8000T-U
& PV-10000T-U. Two paralleled DC feeds from one common
PV string and a single DC feed from another independent PV
string MUST BE set up for PV-15000T-U in accordance with
hardware specifications. The inverter will then adjust to
optimal performance accordingly by itself.
Keep the Sealing Plugs
Please keep those plugs in a safe place. You may need to use
them again in case removal of DC connectors is needed.
Summary of Contents for PV-10000T-U
Page 12: ...11 5 4 Product Labels ...
Page 14: ...13 6 2 Unpacking PV 15000T U ...
Page 15: ...14 6 3 1 Unpacking PV 20000T U ...
Page 16: ...15 6 3 2 Unpacking PV 20000T U E Display ...
Page 17: ...16 6 4 Assembly Chart PV 5000T U PV 8000T U PV 10000T U PV PV15000T U ...
Page 18: ...17 6 5 Assembly Chart PV 20000T U ...
Page 81: ...80 14 Addendum 14 1 Efficiency Charts 14 1 1 PV 5000T U 14 1 2 PV 8000T U ...
Page 82: ...81 14 1 3 PV 10000T U 14 1 4 PV 15000T U ...
Page 83: ...82 14 1 5 PV 20000T U ...
Page 84: ...P N MUB0 A00000 0 ...