Device Installer
Use Hostlist
If this option is set to
True
, the device server scrolls through
the host list until it connects to a device listed in the host list
table. Once it connects, the unit stops trying to connect to any
others. If this connection fails, the unit continues to scroll
through the table until it connects to another IP in the host list.
The host list is disabled for Manual Mode and for Modem
Mode. The unit will not accept a data connection from a
remote device when the host list option is enabled.
LED
Select
Blink
for the status LEDs to blink upon connection or
None
for no LED output.
Disconnect Mode
On Mdm_Ctrl_In Drop
Set to
Yes
for the network connection to or from the serial port to drop
when
modem_control_in
transitions from a high state to a low state.
Hard Disconnect
When set to
Yes
, the TCP connection closes even if the remote site
does not acknowledge the disconnect request.
With EOT
Select
Yes
to drop the connection when
Ctrl-D
or
Hex 04
is detected.
Both
Telnet Mode
and
Disconnect with EOT
must be enabled for
Disconnect with EOT
to function properly.
Ctrl+D
is only detected
going from the serial port to the network.
Inactivity Timeout
Use this parameter to set an inactivity timeout. The unit drops the
connection if there is no activity on the serial line before the set time
expires. Enter time in the format mm:ss, where m is the number of
minutes and s is the number of seconds. To disable the inactivity
timeout, enter
00:00
.
3. When you are finished, click the
OK
button.
4. On the main menu, click
Apply Settings
.
3-16
NET485 User Guide