Device Installer
3.11 Apply Factory Defaults
Click the
Apply Factory Defaults
button to set the device server back to the default settings.
3.12 Configuration Using Telnet
You must configure the unit so that it can communicate on a network with your serial device. The unit’s
configuration is stored in nonvolatile memory and is retained without power. You can change the
configuration at any time. The unit performs a reset after the configuration has been changed and stored.
You can establish a Telnet connection by clicking the Telnet Configuration tab in the Device Installer
window or by starting a Telnet session in command mode.
Telnet Configuration using Device Installer
Click the Telnet Configurarion tab. When the window opens, click the Connect button.
Go to
Telnet Messages
on page 3-22
3.12.1 Telnet Connection
To configure the unit over the network, establish a Telnet connection to port 9999.
Note: If you use the Telnet Configuration tab on Device Installer, skip steps 1and 2.
1.
From the Windows Start menu, click
Run
and type the following command, where x.x.x.x is the IP
address and 9999 is the unit’s fixed network configuration port number.
telnet x.x.x.x 9999
Note:
Be sure to include a space between the IP address and 9999.
2.
Click
OK
.
NET485 User Guide
3-21