8: Setup Mode: Channel Configuration
This chapter explains how to configure the serial port.
Current values display in parenthesis.
You must enter some values in hexadecimal notation. See
Appendix E: Binary to
Hexadecimal Conversions
.
Channel 1 (Option 1)
Select
Channel 1
(Option
1)
from the Change Setup menu to define how the serial port responds
to network and serial communications. The following sections describe the configurable
parameters within the
Channel
configuration menu.
Figure 8-1
Serial Port Settings
Baudrate (9600) ?
I/F Mode (4C) ?
Flow (00) ?
Port No (10001) ?
ConnectMode (C0) ?
Send '+++' in Modem Mode (Y) ?
Show IP addr after 'RING' (Y) ?
Auto increment source port (N) ?
Remote IP Address : (000) .(000) .(000) .(000)
Remote Port (0) ?
DisConnMode (00) ?
FlushMode (00) ?
DisConnTime (00:00) ?:
SendChar 1 (00) ?
SendChar 2 (00) ?
Baudrate
The unit and attached serial device, such as a modem, must agree on a speed or baud rate to
use for the serial connection. Valid baud rates are 300, 600, 1200, 2400, 4800, 9600 (default),
19200, 38400, 57600, 115200, and 230400 baud. NetDirect also supports high-performance
baud rates of 460800 and 921600 bits per second. See
Baudrate (9600) ? _