4
WARNING
OPERATOR SPECIFICATIONS
TYPICAL DOOR INSTALLATION
Power Specifications
Main AC Power Supply
230-240 Vac 50Hz
Max. Pull Force
1,200N
Power
225W
Operating Temperature
+5°C to +40°C
Door Specifications
Max Door Height
3.0m
Max Door Weight
160kg
Max Lift under Spring Tension
20kg
Normal Torque
8Nm
Maximum Door Area
Commercial Spring-Balanced Sectonal Doors up to 15m²
Max. Door Cycles
50 cycles / day
Dimensions
Operator Length
370mm
Rail Length
GLD-R2.4M: 3,222mm / GLD-R3.0M: 3,822mm
Operator Height
100mm
Rail Height
46.5mm
Operator Width
200mm
Rail Width
88mm
Total installed dimensions
GLD-R2.4M: 3,372mm (L) x 150mm (H) x 200mm (W)
GLD-R3.0M: 3,972mm (L) x 150mm (H) x 200mm (W)
Compliance
AS/NZS 60335-1
AS/NZS 60335-2-103
Transmitter Specifications
Hand Transmitters
64 devices
Keypad Transmitters
2 devices
Operator Frequency
433.30 / 433.92 / 434.54 MHz
Transmitter Management
Compatible with STAR1000EVO (accessory sold separately)
Usage
Indoor Use Only
Door Types
Commercial spring-balanced sectional
door with curved track, up to 3.0m
high and up to 15m² in area.
A 240V General Purpose Outlet (GPO) ie. Power Point must be available in close proximity to the operator.
This fitting is not part of the operator hardware and must be supplied by the consumer.
INTRODUCTION