background image

44

CHAMBERLAIN LIMITED WARRANTY 

Grifco® Commercial LG-Drive

Slide Gate Opener

Chamberlain Australia Pty Limited / Chamberlain New Zealand Limited 

(Chamberlain)

, the manufacturer of Grifco® automatic gate openers, is committed to manufacturing 

and supplying high quality goods. As part of this commitment, we seek to provide reliable service 

and support for our goods and are pleased to provide you, the original purchaser, with this 

Chamberlain Limited Warranty. 

The benefits given to you under this Chamberlain Limited Warranty are in addition to any rights and 

remedies that you may have under Australian or New Zealand consumer protection laws. Our goods 

come with guarantees that cannot be excluded under the Australian Consumer Law, or New Zealand 

Consumer Guarantess Act 1993. You are entitled to a replacement or refund for a major failure and 

for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have 

the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not 

amount to a major failure.

Chamberlain’s warranty

What is covered

Chamberlain warrants to the original purchaser of the Grifco Slide Gate Opener (Unit) that all parts of 

the Unit, other than remote controlled transmitters, battery back up units, accessories, globes and 

batteries, are free from defects in materials and workmanship for a period of 36 months or 15,000 

cycles (each opening & closing of the gate equals 1 cycle) whichever comes first, from the date of 

purchase when installed by a Professional dealer appointed or authorised by Chamberlain on a 

typical gate installation within the indicated specifications.

Chamberlain warrants that the remote controlled transmitters (E960G) included with the Unit are free 

from defects in materials and workmanship for a period of 24 months from the date of purchase and 

all other accessories included with the Unit are free from defects in materials and workmanship for a 

period of 12 months from the date of purchase.

What is not covered

 

Batteries and globes are not covered under the Chamberlain Limited Warranty. 

Travel costs incurred by Chamberlain or the Professional Dealer in either travelling to or from areas 

outside a capital city metropolitan area. These costs will be at the purchaser’s expense. 

Additional access costs incurred by a Professional Dealer or Chamberlain in obtaining access where 

the Unit is not readily accessible. These cost will be at the purchaser’s expense.

Warranty Conditions

 

It is a condition of this Chamberlain Limited Warranty that the Unit is sold, installed and serviced by a 

Professional Dealer appointed or authorised by Chamberlain. A Grifco branded gate opener 

purchased over the internet and installed by a person other than a Professional Dealer will not be 

covered by this Chamberlain Limited Warranty.

It is also a condition of this Chamberlain Limited Warranty that for the operating life of the Unit: 

1 the gate and the Unit is professionally maintained and serviced by a Professional Dealer during the  

   Chamberlain Limited Warranty period such that the gate operates according to manufacturer 

   specifications. If your gate binds or sticks, then it must not be  used until serviced by a trained 

   gate technician or Profesional Dealer. The gate service fee will be at the purchaser’s expense;

2 the warranty is registered by completing the online form at

   www.grifco.com.au or www.grifco.co.nz; and

3 you retain your sales docket or invoice as proof of purchase, and attach it to this manual to enable   

   you to establish the date of purchase in the unlikely event of a warranty service being required.

Making a claim

 

During the applicable Chamberlain Limited Warranty period, if you are concerned that the Unit may 

be defective, call the Professional Dealer that sold/installed the opener, or our service centre on the 

toll free number below and a Chamberlain technician will diagnose the problem and arrange for this 

to be rectified. 

Once the problem has been diagnosed, subject to your rights under the applicable Australian and 

New Zealand consumer protection laws with respect to major failures, Chamberlain or its 

Professional Dealer will provide you with either, repairs to the Unit or a replacement Unit.Repairs and 

replacement parts provided under this Chamberlain Limited Warranty are provided free of charge 

and are warranted for the remaining portion of the original warranty period.

This Chamberlain Limited Warranty provides benefits which are in addition to your other rights and 

remedies as a consumer.

Exclusions - what voids the warranty 

If our service centre determines that a warranty claim has been made in respect of a failure or defect 

arising under or out of any exclusion detailed below such that the claim is not covered under this 

Chamberlain Limited Warranty, we may, subject to your other rights and remedies as a consumer, 

charge you a fee to repair, replace and/or return the Unit to you.

This Chamberlain Limited Warranty does not cover any failure of, or defect in, the Unit due to: 

1  non-compliance with the instructions regarding specifications, installation, operation, maintenance 

    and testing of the Unit or of any product with which the Unit is used; 

2  any attempt by a person other than a Professional Dealer to repair, dismantle, reinstall or move 

    the Unit to another location once it has been installed;

3  use of any copy, imitation or replica gate remotes with your Grifco Unit; 

4  tampering, neglect, abuse, wear and tear, accident, electrical storm,excessive use or conditions  

    other than normal use; 

5  problems with, or relating to, the gate or gate hardware,

6  problems caused by electrical faults or replacement of batteries or light bulbs, blown fuses, 

    electrical surges, power surges or power strikes, fire, flood, lightning or storms;

7  corrosion caused by sea air if located near a waterway, beach etc; 

8  lack of proper maintenance, service or care of the gate and Unit; 

9  any unauthorised modification to the Unit; or 

10 damage caused by insects, pests or other after sale damage caused by events or accidents 

    outside Chamberlain’s reasonable control and not arising under normal and standard operating  

    conditions.

NB: A General Purpose Outlet (GPO) ie: power point must be supplied by the consumer as this 

electrical fitting does not form a part of the Unit (opener).

If this Chamberlain Limited Warranty does not apply, you may have rights available to you under the 

Australian and New Zealand consumer protection laws.

Liability – Australia only

 

Except as set out in the Australian Consumer Law (being Schedule 2 of the Competition and 

Consumer Act 2010) (as amended, consolidated or replaced): 

1 all other guarantees, warranties and representations in relation to the Unit or its supply are 

   excluded to the extent that Chamberlain can lawfully exclude them; and 

2 under no circumstances will Chamberlain be liable for consequential, incidental or special damages 

   arising in connection with the use, or inability to use, the Unit, other than those which were 

reasonably foreseeable as liable to result from the failure.

Liability – New Zealand only

 

Except as set out in the Fair Trading Act 1986 and the Consumer Guarantees Act 1993 (as 

amended, consolidated or replaced): 

1  all  other  guarantees,  warranties  and  representations  in  relation  to  the  Unit  or  its  supply  are                                                   

   excluded to the extent that Chamberlain can lawfully exclude them; and 

2 under no circumstances will Chamberlain be liable for consequential, incidental or special damages  

   arising in connection with the use, or inability to use, the Unit, other than those which were 

   reasonably foreseeable as liable to result from the failure.

Note

 

Chamberlain reserves the right to change the design and specifications of the Unit without prior 

notification. Some features or accessories of the Unit may not be available in certain markets or 

areas. Please check with your distributor.

Chamberlain service centre contact details

Australia 

 

Phone toll free 1800 474 326  
Fax toll free 1800 888 121  
Unit 1, 75 Epping Road North Ryde, NSW 2113

Website www.grifco.com.au 

Email customerservice@chamberlainanz.com 

New Zealand 

 

Auckland phone 09 477 2823  
Phone toll free 0800 653 667  
Fax toll free 0800 653 663 

Website www.grifco.co.nz

WARRANTY

Summary of Contents for LG Drive GGS1000

Page 1: ...patible with Security 2 0 accessories Compatible with Grifco Battery Backup and myQ Internet Gateway Slide Gate Opener GLD GO GLD GO LV Installation and Operating Instructions INSTRUCTION MANUAL Compa...

Page 2: ...ates a potentially hazardous situation which if not avoided could result in death or serious injury Indicates a potentially hazardous situation which if not avoided could result in minor or moderate i...

Page 3: ...y respecting the given safety distances in accordance with the AS NZS 60335 1 in conjunction with AS NZS 60335 2 103 and or with safety devices e g safe edge Testing of the safety function of the driv...

Page 4: ...Initial Setup 20 BASIC SETTINGS 21 26 Limit and Force Learning 21 Remote Control Behaviour 21 IR Behaviour 21 Input Command 22 Pedestrian Command 22 Delay Motor 2 in Open and Close Direction 22 23 Tim...

Page 5: ...tains the opener its hardware accessories four metres of rack and a transformer MGTR3 120VA only for the GLD GO LV sales kit Main AC Supply 220 240Vac 50 60Hz Motor Voltage 24 Vdc Input Power 150 W Am...

Page 6: ...play in the gate area Moving Gate Can Cause Serious Injury Or Death 132A3224 01 WARNING Warning Label placed within the inside of the post Transformer Box mounted near 240V power supply MGTR3 120VA N...

Page 7: ...that the Low Voltage LV power cable is run inside conduit to the opener as per local installation requirements Suitable cable glands must be used that provide sufficient cable restraint against a mini...

Page 8: ...ight 1000kg Maximum Gate Width 12m Conduit and Concrete Pad Trench and install conduit Before trenching contact underground utility authorities Conduit must be approved for low and mains voltage Consi...

Page 9: ...ith a minimal distance of approximately 1 2cm between the rollers and gate Safety Safety entrapment protection devices are recommended to protect against any entrapment or safety conditions encountere...

Page 10: ...plate Rack 270 mm 170 mm 60 mm Underneath the mounting plate is the concrete slab one of the two limit switch brackets Mounting plate Rack Rack 90 100mm Rack Rack Gate Rack 2 3mm PLANNING CONTINUED 6...

Page 11: ...ounting plate 90 100mm Rack 1 Position the base mounting plate as required referring to the planning section figure 1 2 Mark and drill the four masonry anchor holes figure 2 NOTE Position the power co...

Page 12: ...t of the drive gear with the gate rack figure 1 figure 2 1 Manually move the gate into OPEN position 2 The nylon rack can be attached with screws Put the first rack segment at the end of the gate so t...

Page 13: ...g cover over the opener and move the gate manually to the open and close positions to ensure that the limit switch brackets do not come into contact with the gate structures or the gate opener Positio...

Page 14: ...ns be sure to follow all specifications and warnings Failure to do so may result in SEVERE INJURY to persons and or damage to the opener ALL electrical connections MUST be made by a licensed electrici...

Page 15: ...ain access to the control board remove the opener cover The terminals for wiring accessories are directly accessible To get access to the programming buttons remove the transparent plastic cover and p...

Page 16: ...0 0 0 4 3 2 1 1 2 3 3 1 2 1 2 12 13 14 4 11 10 9 8 7 6 5 1 3 2 3 4 2 1 3 2 1 2 1 3 2 1 3 2 1 2 1 1 2 1 2 2 1 2 1 1 2 1 2 5 4 3 2 1 6 7 8 9 10 2 1 1 1 1 2 1 1 1 1 Dual driver primary secondary SYNC Du...

Page 17: ...r can only be connected to the Edge inputs 1 Remove the 8 2k resistor from the Edge inputs 2 Connect the 8 2k compatible edge sensor to the Edge inputs EDGE SE SE IR SENSOR GND IR3 IR2 IR1 COMMAND GND...

Page 18: ...change the value on display The programming of the boards is divided in two steps 1 Basic including Initial Setup 2 Advanced Password Protected Settings Initial Set up includes Selection of motor typ...

Page 19: ...E Lock E Lock 30 Ram Blow Setup additional electronic lock E Lock or Mag Lock options 31 Flashing Light Setup flashing light accessory 32 Pre Flashing Adjust pre flashing of flashing light accessory 3...

Page 20: ...tion has been confirmed the screen will change to MAIN MENU DIRECTION MOTOR If there is a second slide gate opener to be setup press the button to scroll to the next menu option MAIN MENU DIRECTION MO...

Page 21: ...tons to navigate through the options 3 You can select the following options OPEN CLOSE OPEN OPEN STOP CLOSE STOP OPEN STOP CLOSE OPEN OPEN ONLY 4 To confirm the setting press the P button to save and...

Page 22: ...e following options No Second Delay Second Delay 3 Second Delay 4 Second Delay 4 To confirm the setting press the P button to save and return to the main menu screen S P MAIN MENU DELAY MOTOR 2 OPEN f...

Page 23: ...ELAY MOTOR 1 CLOSE figure 1 TIMER TO CLOSE TTC 28 Within the Basic Setting navigate through the menu screen until you find MAIN MENU TIMER TO CLOSE 1 Press the P button to enter this setting figure 1...

Page 24: ...COND REVERSAL S P REVERSE TO LIMIT S P CLOSE REV TO OPEN LIMIT OPEN REV 2 SECONDS figure 1 figure 2 figure 3 figure 4 BASIC SETTINGS E LOCK 30 Within the Basic Setting navigate through the menu screen...

Page 25: ...U FLASHING LIGHT 1 Press the P button to enter this setting figure 1 2 Press the or buttons to navigate through the options 3 You can select the following options Disabled Continuous Flashing 4 To con...

Page 26: ...ind MAIN MENU SOFT HARD START SETTING 1 Press the P button to enter this setting figure 1 2 Press the or buttons to navigate through the options 3 You can select the following options Soft Hard Start...

Page 27: ...WORD CHANGE PASSWORD S P ENTER OLD PW 0000 S P ENTER NEW PW 0000 figure 1 figure 2 figure 3 CHANGE PASSWORD 1 Navigate the Menu screen till you get to MAIN MENU PASSWORD by pressing the and or buttons...

Page 28: ...e force by 15 30 or 50 4 To confirm the setting press the P button to save and return to the main menu screen PASSWORD 37 ENTER PASSWORD 1 Navigate the Menu screen till you get to MAIN MENU PASSWORD b...

Page 29: ...you find MAIN MENU SPEED MOTOR 1 2 CLOSE PW 1 Press the P button to enter this setting figure 1 2 Press the or buttons to navigate through the options 3 You can increase the speed by 25 50 75 or 100 I...

Page 30: ...this setting figure 1 2 Press the or buttons to navigate through the options 3 You can select the following options Execute Factory Reset Exit 4 To confirm the setting press the P button to save and...

Page 31: ...NDBY screen NOTE The transmitter s supplied with your opener are preprogrammed by the factory If you purchase additional transmitters the gate opener must be programmed to accept the new transmitter c...

Page 32: ...compatible Ensure the Grifco gate opener is installed Purchase the gate myQ Connectivity Kit that includes 1 x myQ Gateway and 1 x 772ANZ Protector System Safety IR Beams Ensure the 772ANZ Protector...

Page 33: ...th the gate myQ Connectivity Kit or as an individual accessory NOTE The Protector System Safety IR Beams 772ANZ must be installed and operational for myQ to operate myQ Gateway Connect the myQ Gateway...

Page 34: ...BER from the bottom label of the myQ Gateway The serial number is a series of ten characters 0 9 or a f Be sure to use the correct characters e g a zero 0 instead of an O and keep the character spacin...

Page 35: ...m Check for incorrect accessories wired into the IR terminals Check the Protector System for alignment or an obstruction Auto reset once obstruction is clear or Protector System is realigned may take...

Page 36: ...te Auto reset once the issue has been resolved may take up to 16 seconds ERR MOTOR1 RPM ERR MOTOR2 RPM Motor is stalled or RPM is damaged Check if the motor is stalled or RPM is damaged Auto reset onc...

Page 37: ...t shown 18 002A2331 6 Pin Wire Harness not shown 19 Model Vary Flashing Lamps not shown 20 Model Vary Sounders not shown 21 PU100 Emergency Stop Switch not shown 22 AT000 Timer 24h not shown WARNING T...

Page 38: ...GGS1000 Articulated Arm Single Articulated Arm Dual Linear Arm Single Linear Arm Dual 2nd Direction Motor 1 Press Hold Gate Opening Yes P no S Change Direction P to Execute 3rd Direction Motor 2 Chang...

Page 39: ...Remote Control Behaviour Open Only Open Stop Close Stop Open Stop Close Open Open Close Open IR 1 2 3 Behaviour IR1 2 3 CLOSE DIR IR1 2 3 OPEN DIR IR1 2 3 OPEN CLOSE DIR IR1 2 3 CLOSE DIR IMMEDIATE C...

Page 40: ...ing TTC 20 Seconds Setting TTC 30 Seconds Setting TTC 45 Seconds Setting TTC 1 Minute Setting TTC 2 Minutes Setting TTC 3 Minutes Setting TTC 5 Minutes Disable Ram Blow 1 Second Ram Blow 2 Seconds Rev...

Page 41: ...30 Seconds 45 Seconds 60 Seconds 90 Seconds Soft Hard Start Setting 120 Seconds 180 Seconds 240 Seconds 300 Seconds Disabled 1 Second 2 Seconds 3 Seconds 4 Seconds 5 Seconds Soft Start Enabled Hard S...

Page 42: ...ncrease 30 Increase 50 Soft Stop Speed PW Factory Default Learned Speed Decrease 10 Decrease 20 Decrease 30 Decrease 50 Increase 10 Increase 20 Learned Speed Increase 25 Increase 50 Increase 75 Increa...

Page 43: ...y or grifco co nz warranty Get Connected with Visit www grifco com au or www grifco co nz for more details Additional purchase of the myQ Connectivity Kit is required to enable myQ functionality DON T...

Page 44: ...o your rights under the applicable Australian and New Zealand consumer protection laws with respect to major failures Chamberlain or its Professional Dealer will provide you with either repairs to the...

Reviews: