COMPONENT MAINTENANCE MANUAL
IN 1502H RADAR INDICATOR
TM109102
4-19
May/01
IN-1502H ALIGNMENT
DATA SHEET (2 of 2)
Serial Number: ___________________
Flavor_________________
PROC
MPS
TEST
MEASLIMITS/
STEP
REF
DESCRIPTION
DATACONDITIONS
5.N.2
Focus
________ OK
Optimum Focus
5.O.8
VCO Adjustment
________ OK
+4.0 ± 0.05 VDC
5.P.2
Brightness Gain
________ OK
0 ± 0.01 VDC
5.P.4
Brightness Cal
________ OK
+3.0 ± 0.02 VDC
5.P.5
Brightness Range
________ OK
0 ± 0.01 to
+3.0 ± 0.02 VDC
5.Q.10
Horizontal Retrace
________ OK
Horz. retrace lines not
visible
5.Q.12
Gain Control
________ OK
+6.0 ±1.0 VDC
5.Q.13
Luminance Bars
________ OK
No bleeding of
luminance bars
5.R.7
Vertical Position
________ OK
Slight vert. overscan
5.R.8
Vertical Size
________ OK
Slight vert. overscan
5.S.1
Horizontal Position
________ OK
10K ± 10
Ω
5.S.3
Horizontal Position
________ OK
Display centered
5.S.4
Horizontal Size
________ OK
Slight horz. Overscan
5.T.6
Vertical Position
________ OK
Display centered
5.T.7
Vertical Size
________ OK
Slight vert. overscan
5.U.1
Horizontal Position
________ OK
Display Centered
TEST PERFORMED BY:
DATE: