COMPONENT MAINTENANCE MANUAL
IN 1502H RADAR INDICATOR
TM109102
5-3
May/01
B. Recommended Cleaning Procedures
WARNING: GOGGLES ARE TO BE WORN WHEN USING PRESSURIZED AIR TO
BLOW DUST AND DIRT FROM EQUIPMENT. ALL PERSONNEL SHOULD
BE CLEARED FROM THE IMMEDIATE AREA.
WARNING: OPERATIONS INVOLVING THE USE OF A CLEANING SOLVENT
SHOULD BE PERFORMED UNDER A VENTILATED HOOD. AVOID
BREATHING SOLVENT VAPOR AND FUMES. AVOID CONTINUOUS
CONTACT WITH THE SOLVENT.
CAUTION:
USE ONLY RECOMMENDED CLEANING SOLVENTS ON ELECTRICAL
PARTS. MANY AVAILABLE CLEANING SOLVENTS CAN SOFTEN AND
PERMANENTLY DAMAGE INSULATING MATERIALS.
CAUTION:
ALUMINUM ELECTROLYTIC CAPACITORS CAN BE DAMAGED BY
HALOGENATED HYDROCARBON SOLVENTS. TELEPHONICS
RECOMMENDS ISOPROPYL ALCOHOL AS A SAFE CLEANING
SOLVENT FOR PRINTED CIRCUIT BOARDS CONTAINING ALUMINUM
ELECTROLYTIC CAPACITORS. OTHER SOLVENTS WHICH MAY BE
USED ARE AS FOLLOWS:
SAFE SOLVENTS
XYLENE
ETHYL ALCOHOL
BUTYL ALCOHOL
METHYL ALCOHOL
PROPYL ALCOHOL
CALGONITE (a brand of detergent)
PRINTED CIRCUIT BOARDS CONTAINING ALUMINUM ELECTROLYTIC
CAPACITORS SHALL NOT BE CLEANED WITH THE FOLLOWING
SOLVENTS:
UNSAFE SOLVENTS
FREON TF, FMC
CARBON TETRACHLORIDE
CHLOROFORM
TRICHLOROETHYLENE
TRICHLOROETHANE
ALL (a brand of detergent)
METHYLENE CHLORIDE
The document reference is online, please check the correspondence between the online documentation and the printed version.