Insufficient chimney draft.
•
Low quality or wet combustion material.
•
Blockage in the chimney or flue channels of the heater.
•
The stones are laid incorrectly.
Troubleshooting methods:
•
Check that the compliance of the heater capacity against the sauna size (section 1).
•
Check combustion material for compliance with the requirements (paragraph 2.4).
•
Perform maintenance (paragraph 2.8).
•
Inspect the stone heater for compliance with the requirements (paragraph 2.5).
Remove stone chips and replace them with intact stones. Replace the stones with
diameters less than the ones specified in Table 1 with larger ones.
4) Fault:
The operating mode of the heater cannot be controlled during wind /heater firing/
low chimney draft during operation. Smoke partly escapes through the firebox door. Smoke
enters the sauna.
Possible cause:
•
Blockage in the chimney or flue channels of the heater.
•
The chimney height is not sufficient or the chimney is located next to a high obstacle.
•
There is cold air in the chimney; the chimney has not heated up.
•
Low quality or wet combustion material.
•
The chimney is installed incorrectly.
Troubleshooting methods:
•
Perform maintenance (paragraph 2.8).
•
Extend the chimney stack height.
•
Insulate the chimney stack with a non-combustible heat-insulation material.
•
Select a heat-insulated chimney stack.
•
Remove ash from the ash drawer.
•
Check combustion material for compliance with the requirements (paragraph 2.4).
•
Ensure supply of a sufficient volume of combustion air.
•
Check the correctness of chimney installation and/or compliance with the
manufacturer’s requirements; trust the installation and disassembly of the chimney
only to qualified specialists.
3. INSTALLATION MANUAL
3.1. Before commencing installation of the he
a
ter
IMPORTANT! Make sure that all safety distances around the heater are observed. There
shall be no electrical appliances, cables, meltable and flammable materials within the
safety distances. Consider the safety distances from the chimney during installation!
•
The heater shall be installed in compliance with all local rules, including those referring to
European and national standards.
•
The chimney stack for the heater shall be individual, not joint combined for several
appliances.
•
For more information about fire safety requirements, please, address the local fire
department.
•
Check the availability of all the heater component parts. Make sure that all the heater
bolted connections are tightened.
Summary of Contents for Aurora
Page 24: ...24 24 615 Aurora 160 TRIO Short 460 1430 240 210 385 375 230 615 ɸ115 ...
Page 25: ...25 25 725 Aurora 160 TRIO Long 460 1430 240 210 385 375 615 230 170 ɸ115 ...
Page 26: ...26 26 750 Aurora 160 TRIO Window 460 1430 650 450 600 460 750 230 200 ɸ115 ...
Page 46: ...46 Figure 5 Stone chimney connection Figure 6 Steel chimney connection ...
Page 52: ...52 615 Aurora 160 TRIO Short 460 1430 240 210 385 375 230 615 ɸ115 ...
Page 53: ...53 725 Aurora 160 TRIO Long 460 1430 240 210 385 375 615 230 170 ɸ115 ...
Page 54: ...54 750 Aurora 160 TRIO Window 460 1430 650 450 600 460 750 230 200 ɸ115 ...
Page 80: ...80 615 Aurora 160 TRIO Short 460 1430 240 210 385 375 230 615 ɸ115 ...
Page 81: ...81 725 Aurora 160 TRIO Long 460 1430 240 210 385 375 615 230 170 ɸ115 ...
Page 82: ...82 750 Aurora 160 TRIO Window 460 1430 650 450 600 460 750 230 200 ɸ115 ...