1 Operation

2 Safety

2.1 Symbol

2.2 Intended use

2.3 Environmental and operating conditions

2.4 Safety indication

Dangers may arise from the unit, if:

the product is not installed or inserted properly,

the system is not used for its intended purpose,

the safety and installation notes are not observed. 

CAUTION! Never operate the hand lever when the load is suspended!

Rev. 1.01

2

To open the change system, pull the locking pin on the hand lever. After that the hand lever is to be opened 
by approximately 90°. With the help of the hand lever the semi-cylindrical bolt can be turned counter 
clockwise (“to the left”) by 180° up to the stop. The upper and lower assembly can now be pulled apart. 
When joining the parts, the hand lever must be set to open position. It cannot lock in this position. 
Now, upper and lower assembly can be pushed into each other.
By turning the semi-cylindrical bolt clockwise (“to the right”) 180° up to the stop, the system is locked. 
Afterwards the hand lever is folded and latched.

The MGW Connector has been designed as an interface between handling device and tool (e.g. 
gripper). Furthermore, the MGW can also be used in special solutions, automation and also as a 
general mechanical standard interface. The unit may only be used in the context of its technical 
specifications. The system is intended for the installation in a machine. The requirements of the 
applicable instructions must be considered and adhered to.

NOTICE! 

The unit may only be operated if the machine in which the unit is installed complies with 
the relevant provisions of the machinery directive 2006/42/EC.

This symbol indicates possible hazards to persons or the MGW 
Connector.

Use this unit only in dry and splash-proof environments at room temperature as well as within the 
application parameters defined in the technical specifications. If this is not the case, warranty 
cannot be accepted. Exceptions are units designed especially for the respective conditions.

Everyone who is responsible for assembly, commissioning and maintenance must read and 
understand the complete operating instructions. Improper use, which affects the function und 
operational safety of the MGW Connector, is prohibited.

In order to prevent damage to the connector as well as injuries to the operator, the 
lower assembly or the tool must be secured by hand or other devices before opening 
the exchange system. Otherwise there is a risk that irreparable damages to the tool or 
injury to the operator are caused by the unit falling down. 

Summary of Contents for G-MGW

Page 1: ...t regards Your GRIP GmbH GRIP GmbH Handhabungstechnik Alter Hellweg 70 Tel 49 231 96450 01 info grip gmbh com 44379 Dortmund Germany Fax 49 231 96450 50 www grip gmbh com MGW Connector Rev 1 01 1 5 7 1 Disassembly 7 2 Torque specifications 1 2 9 2 4 Safety indication Scope of delivery Technical data 8 10 2 2 Intended use 2 3 Environmental and operating conditions 3 4 6 7 3 2 Assembly Maintenance a...

Page 2: ...d in special solutions automation and also as a general mechanical standard interface The unit may only be used in the context of its technical specifications The system is intended for the installation in a machine The requirements of the applicable instructions must be considered and adhered to NOTICE The unit may only be operated if the machine in which the unit is installed complies with the r...

Page 3: ...24 months from the ex works delivery date under observance the mandatory maintenance and lubrication intervals and the given operating conditions Generally parts touching the work piece and wear parts are not part of the warranty Wear parts are listed in chapter 8 1 The unit is considered to be defective if its basic function Lock is no longer functioning Behold technical data sheets TD MGW050 EN ...

Page 4: ...nal diameter That means a change system with the installation size 160 is capable of using the lower assembly 160 12 13mm There is a fitting bore available for the angular orientation for sizes MGW050 to MGW080 For the installation sizes MGW100 to MGW160 there are two fitting bores on the flange surfaces These are designed according to ISO 9409 The upper assembly of the MGW Connector is mounted on...

Page 5: ...shown in image 3 The use of a centering disc ensures that the upper assembly and or lower assembly of the Connector are properly centered Installation on both the upper assembly and lower assembly is possible as shown in image 4 Image 3 Image 4 The MGW is virtually maintenance free Check the semi cylindrical bolt in regular intervals for correct function Keep the mating surface and the moving part...

Page 6: ... 01 6 2 Semi cylindrical bolt VA EG MGW HB V Pos Description Order No 3 Hand lever EG MGW HH 1 Semi cylindrical bolt EG MGW HB 7 Setscrew 1 8 Lower assembly 1 5 Cylinder bolt 1 6 Spring locking pin 1 3 Hand lever 1 4 Index pin 1 2 Semi cylindrical bolt 1 Pos Description Quantity 1 Upper assembly 1 ...

Page 7: ...G MGW Assembly and Operating Manual 9 Exploded view Rev 1 01 7 Image 5 Image 6 Upper assembly Lower assembly ...

Page 8: ... product mentioned above may only be put into operation if it has been established applicable that the unit into which the above mentioned product is to be incorporated complies with the provisions of the Machinery Directive 2006 42 EC Systems for the manual and form closed exchange of components such as grippers and tools on robots or receptacles The provisions of the above mentioned directives i...