1 Operation

2 Safety

2.1 Symbol

2.2 Intended purpose

2.3 Environmental and operating conditions

2.4 Safety indication

Dangers may arise from the unit, if:

the product is not installed or inserted properly,

the system is not used for its intended purpose,

the safety and installation notes are not observed. 

CAUTION! Never operate the semi-cylindrical bolt when the load is suspended!

2

NOTICE!

The unit may only be operated if the machine in which the unit is installed complies with 

the relevant provisions of the machinery directive 2006-42-EC.

NOTICE!

A semi-cylindrical bolt safety device must be used for dynamic applications.

Otherwise boundary conditions supplied by the customer, e.g. vibrations can lead to 

automatic lock-out release.

Everyone who is responsible for assembly, commissioning and maintenance must read and 

understand the complete operating instructions. Improper use, which affects the function und 

operational safety of the SWS Connector, is prohibited.

In order to prevent damage to the connector as well as injuries to the operator, the 

lower assembly or the tool must be secured by hand or other devices before opening 

the change system. Otherwise there is a risk that irreparable damages to the tool or 

injury to the operator are caused by the unit falling down. 

This symbol indicates possible hazards to persons or the SWS 

Connector.

The SWS Connector has been designed as an interface between special solutions and automation 

(e.g. gripper). Furthermore, the SWS can also be used as an interface between handling device and 

tool . In dynamic applications, it can only be used with the locking piston. The unit may only be used in 

the context of its technical specifications. The system is intended for the installation in a machine. The 

requirements of the applicable instructions must be considered and adhered to.

Use this unit only in dry and splash-proof environments at room temperature as well as within the 

application parameters defined in the technical specifications. If this is not the case, warranty 

cannot be accepted. Exceptions are units designed especially for the respective conditions.

To open the change system, insert the square socket key on the square of the semi-cylindrical bolt and turn 

counter-clockwise (“to the left") by 180 ° to the stop. The upper and lower assembly can now be pulled apart. 

When joining the parts, the hand lever must be set to open position. Now, upper and lower assembly can be 

pushed into each other.

By turning the semi-cylindrical bolt clockwise (“to the right”) 180° up to the stop, the system is locked. Afterwards 

the hand lever is folded and latched.

Summary of Contents for G-SWS

Page 1: ... best regards Your GRIP GmbH GRIP GmbH Handhabungstechnik Alter Hellweg 70 Tel 49 231 96450 01 info grip gmbh com 44379 Dortmund Germany Fax 49 231 96450 50 www grip gmbh com SWS Connector 1 3 4 5 8 9 10 8 1 Spare and wear parts Assembly Maintenance and care 7 1 Disassembly 6 Exploded view EC Declaration of incorporation 8 7 7 2 Torque specifications 1 2 Contents 2 2 Intended use Operation Safety ...

Page 2: ... that irreparable damages to the tool or injury to the operator are caused by the unit falling down This symbol indicates possible hazards to persons or the SWS Connector The SWS Connector has been designed as an interface between special solutions and automation e g gripper Furthermore the SWS can also be used as an interface between handling device and tool In dynamic applications it can only be...

Page 3: ...onths from the ex works delivery date under observance the mandatory maintenance and lubrication intervals and the given operating conditions Generally parts touching the work piece and wear parts are not part of the warranty Wear parts are listed in chapter 8 1 The unit is considered to be defective if its basic function Lock is no longer functioning SWS as painted in Image 6 depending on the ord...

Page 4: ...ts or other tools If the SWS Connector can not be installed directly adapter flanges must be used Use screws according to DIN 912 For the sizes 50 63 and 80 screws according to DIN 7984 are to be used on the gripper side The screw in depth of the screws must be observed We recommend the use of a medium tight screw lock Optionally the SWS can be provided with a MEK Energy Coupling To mount the MEK ...

Page 5: ... in image 3 The use of a centering disc ensures that the upper assembly and or lower assembly of the Connector are properly centered Installation on both the upper assembly and lower assembly is possible as shown in image 4 Image 3 Image 4 The SWS is virtually maintenance free Check the semi cylindrical bolt in regular intervals for correct function Keep the mating surface and the moving parts cle...

Page 6: ...1 Screw VS2 optional 11 Anti rotation protection EG SWS VS2 1 Pos Description Order No Quantity 2 Semi cylindrical bolt Quantity 1 10 Square Socket Key ZG VKS SW 1 EG SWS HB 1 8 size 050 125 size 125 250 Description Upper assembly Semi cylindrical bolt Setscrew Pos Description 1 Upper assembly 2 Semi cylindrical bolt 1 3 Setscrew 1 7 Flap VS2 1 4 Index pin 1 5 Housing VS2 1 8 Cylinder bolt VS2 1 9...

Page 7: ...G SWS Assembly and Operating Manual 9 Exploded view 7 Image 5 Image 6 Upper assembly Lower assembly ...

Page 8: ... time of the declaration He further states that the following essential requirements of the Machinery Directive 2006 42 EC were applied and observed annex I numerics 1 1 2 1 1 3 1 1 5 1 3 2 1 7 4 He further states that the specific technical documentation has been drawn up in accordance with annex VII Part B The following harmonized standard has been applied Safety of Machinery Basic concepts gene...

Reviews: