the remote external push button operates as follows:
• A short pressure on the push button stops/starts the light show;
• A long pressure on the push button turns on/off the units connected
to SecS 36.
to set the “stand-alone/master with external push button” mode:
• Connect the external push button to terminals PB and L of the power supply
terminal board;
• Put dip-switches 10 and 11 into the ON position.
example 1
Device in stand-alone/master mode with: sequence colour number 0, running
speed number 4 and external push button enabled.
oFF
on
Figure 3
connection external push button.
IMPORTANT WARNINGS
• Make all connections with the device off.
• Class I unit: categorically needs grounding.
• Wiring and connections must be carried out by qualified personnel.
• Install the device in a well-ventilated place.
• The device generates heat when in function.