background image

To ensure maximum functionality and light output it is recommended to follow these instructions:

5.1 Cleaning the unit

The unit must be cleaned regularly. Cleaning regularity will depend especially on the environment where the unit

will operate: deposits of dust, smokes or other wastes will reduce the light output performances.

• Clean regularly the glass of the unit.

• Be careful when cleaning the components. Operate in a clean, properly illuminated environment. 

• Do not use solvents which could damage plastic or painted surfaces. 

• Remove left particles by a cotton towel dampened with a glass-cleaning liquid or distilled water.

• Remove smoke and other wastes by a cotton towel dampened with isopropyl alcohol. 

• Dry out by a clean, soft, non-scratching towel or by compressed air.

5.2 Regular checks

• Check electrical connections, especially the ground wiring and the power supply cable.

• Check that the unit is not damaged mechanically. Replace those components which have got deteriorated.

All components of the unit are available as spare parts at 

Griven

dealers. 

Exploded views, wiring diagrams, electronic layouts and advertising brochures are available on request.

To make the job of assistance centres easier, specify serial number and model of the unit which spare parts are

requested for. 

The European Directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE), requires that old li-

ghting fixtures must not be disposed of the normal unsorted municipal waste stream. Old appliances must be

collected separately in order to optimise the recovery and recycling of the materials they contain and reduce

the impact on human health and the environment.

The crossed out “wheeled bin” symbol on the product reminds you of your obligation, that when

you dispose of the appliance it the must be separately collected.

Consumer should contact their local authority or retailer for information conceming the correct di-

sposal of their old appliance.

5.0 Maintenance

Attention! 

Always remove mains power prior to opening up the fixture.

6.0 Spare parts

7.0 Disposal

14

English

Summary of Contents for JADE 9 EASY

Page 1: ...JADE 9 EASY Manuale di istruzioni Instructions manual ...

Page 2: ... 1 1 4 Weather protection 10 1 2 Compliance 10 2 0 Size 11 3 0 Packaging and transport 11 3 1 Packaging 11 3 2 Transport 11 4 0 Installation 12 4 1 Fixing 12 4 2 Adjusting light beam direction 12 4 3 Connection to mains power 13 5 0 Maintenance 14 5 1 Cleaning the unit 14 5 2 Regular checks 14 6 0 Spare parts 14 7 0 Disposal 14 8 0 Technical specifications 15 ...

Page 3: ... described in this manual 1 1 2 Installation Fix the unit with screws hooks or any other support able to bear the weight of the unit itself The unit installation actions must be performed by a qualified staff 1 1 3 Protection against burns and fire Suitable to be installed onto normally inflammable surfaces The unit is not to be installed in places where the ambient temperature exceeds 40 104 F 1 ...

Page 4: ...Size 116mm 4 57in 114mm 4 47in 194mm 7 62in 19 3mm 0 76in Ø 8 m m 0 3 1 i n Ø 8 5 0 m m 0 3 3 i n 114mm 4 47in Ø 160mm 6 30in 3 0 Packaging and transport Warning Griven S r l liability will cease upon consignment of goods to the forwarder claims for damage due to trans port must be addressed directly to the forwarder Griven S r l will accept claims for broken or missing goods only within seven day...

Page 5: ...an operate in any position Use the holes Ø8 5 1 4 in the bracket to fix the unit 4 2 Adjusting light beam direction 1 Untighten the lateral screw 2 2 Rotate the bodies of the unit towards desired direction and tighten the screw 2 4 0 Installation 19 3mm 0 76in Ø 8 m m 0 3 1 i n Ø 8 5 0 m m 0 3 3 i n 2 ...

Page 6: ...tures are compatible with the unit features The unit must never be installed if not grounded electrically It is suggested to use a magnetothermic switch along the power supply line as prescribed by in force rules The unit must not be powered up through a dimmer power device Wiring and connection actions are to be performed by a qualified staff Live Ground Neutral Brown Yellow Green Blue Main suppl...

Page 7: ...ce those components which have got deteriorated All components of the unit are available as spare parts at Griven dealers Exploded views wiring diagrams electronic layouts and advertising brochures are available on request To make the job of assistance centres easier specify serial number and model of the unit which spare parts are requested for The European Directive 2002 96 EC on Waste Electrica...

Page 8: ...trical features Voltage 200 250 Vac 50 60Hz Nominal current 0 2A 230V Maximum power 23W Thermal protection Electronic Light output source Type of light output source 9 Leds Optics Optical system Lenses Available optics Spot Narrow Medium Wide Extra Wide Elliptical Elliptical wide Construction Unit body Iron Aluminium Treatment Scratch resistant black paint Weather protection rate IP66 8 0 Technica...

Page 9: ...a Bulgaria 16 46042 CASTEL GOFFREDO MN Italy Telefono 0376 779483 Fax 0376 779682 0376 779552 http www griven com e mail griven griven com http www griven it e mail griven griven it User s manual rel 2 10 ...

Reviews: