H2933, H2934, G0447, & G0581 Update
(Mfd. Since 1/14)
-11-
Control Panel Electrical Diagram
(H2933/H2934/G0447)
Replaces Page 43
DIGITAL AMP
METER
DIGITAL PANEL
SANDING
BELT START
SWITCH
SANDING
BELT STOP
SWITCH
B L U E
B L A C K
3
1
4
2 1
4 3
2
1 4
1 4
1 4
1 3
1 3
1 3
2 1
2 1
2 2
2 2
X 1
X 2
5
6
2
3
9
8
1 1
U 1 V 1 W 1 U 2 V 2 W 2
18 19 13 12 11 10 9 8 6 5 5 3 3 2
1 5
7
16
1 2 V
O V
B
X 1
X 2
1 0
1 4
1 3
2 1
2 2
X 1
X 2
1 4
1 3
14
18
1
2
4
3
2
3
1 4
1 5
1 1 1 0 9 8 7 6 5 4 3 2 1
1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 2 1 2 2
7
CONVEYOR
BELT START
SWITCH
POWER
LAMP
EMERGENCY
STOP
BUTTON
CONVEYOR
BELT STOP
SWITCH
1
3
2
4
1
2
3
4
5
3
5
3
BELT TRACKING
LIMIT
SWITCH
BELT TRACKING
LIMIT
SWITCH
TABLE UP/DOWN
SAFETY LIMIT
SWITCH
TABLE UP/DOWN
SAFETY LIMIT
SWITCH
OUT TO
SANDING
MOTOR
TABLE HEIGHT SENSOR
B L U E
B L A C K
A
16 17
1
2
4
3
5
5
3
3
EMERGENCY
STOP AND
BELT TENSION
LIMIT SWITCHES