To install the air line:
1. Connect the hose from your air compressor
to the air inlet (
Figure 10) on the regulator.
Air Inlet
Air ON/OFF
Lever
(Open Position)
Regulator
Knob
2. Make sure the red handle on the regulator
is in the open position (parallel with the air
inlet).
3. Lift the regulator knob (Figures 10 and 11)
and turn it until the air pressure gauge reads
75 PSI.
Note: Turn the knob clockwise to
increase the air pressure and counterclock-
wise to lower the air pressure.
4. Push the regulator knob down until it snaps.
Beginning Assembly
Complete the assembly in the order provided in
this manual. Then read the rest of the manual
before attempting any type of sanding operation.
Your safety is important! Please follow the
warnings below during this entire section:
Disconnect power to the
machine for the assem-
bly process. Failure to
do this may result in
serious personal injury.
Figure 10. Air inlet located on regulator.
Air Line Installation
Figure 11. Regulator knob.
Dust Collection
Figure 12. Typical three-port configuration.
An efficient and clean dust collection system is
essential to the proper function of the sander.
Ensuring a healthy work environment is also
dependent upon cleaning and maintaining your
dust collection system. For the H2933/H2934/
G0447 we recommend a minium of: 2400 CFM,
and for the G0581: 4000 CFM is recommended.
To hook up a dust collection system:
1. Install the dust ports (Figure 12) to the
mounting locations on the top of the sanding
unit with the supplied M6-1 x 10 Phillips head
screws.
2. Using 4" hose clamps, secure the hoses
from your dust collection system to the dust
ports.