Model G0568/G0569 (Mfd. Since 10/11)
Phase Converter Precaution
The power from the manufactured leg may dam-
age electrical components if connected to the
wrong incoming power terminal on your machine.
Only connect the manufactured leg to the terminal
indicated on the wiring diagram.
DO NOT use a
static phase converter, as they are known to
damage electrical components.
The Model G0569 is convertable to 440V opera-
tion. This conversion job consists of disconnect-
ing the saw from the power source, changing the
connections on the magnetic switch and rewiring
the motor for 440V operation.
The Model G0569 440V Conversion Kit (Part
P0569082A) for this procedure can be purchased
by calling Grizzly Customer Service at (800) 523-
4777.
440V Conversion
Figure 14. Typical setup of a permanently
connected machine.
Power
Source
Locking
Disconnect Switch
Machine
Ground
Ground
Conduit
Conduit
Grounding Instructions
In the event of a malfunction or breakdown,
grounding provides a path of least resistance
for electrical current to reduce the risk of electric
shock. A permanently connected machine must
be connected to a grounded metal permanent wir-
ing system; or to a system having an equipment-
grounding conductor. All grounds must be verified
and rated for the electrical requirements of the
machine. Improper grounding can increase the
risk of electric shock!
3. Install the 440V magnetic switch and wire it
according to the
G0569 Wiring Diagram on
Page 66.
4. Remove the motor junction box cover, rewire
the motor as shown on the diagram located
inside the junction box, then reinstall the
cover.
Note: The reference wiring diagram on Page
66 was current at the time of printing, but
always use the wiring diagram provided
inside the motor junction box, as it will reflect
any changes to the motor shipped with your
machine.
Figure 15. 220V magnetic switch
Extension Cords
Since this machine must be permanently con-
nected to the power supply, an extension cord
cannot be used.
To rewire the Model G0569 for 440V operation:
1. DISCONNECT MACHINE FROM POWER!
2. Remove the magnetic switch cover, then
disconnect the 220V magnetic switch (see
Figure 15).
All wiring changes must be inspected by a quali-
fied electrician before the saw is connected to the
power source. If, at any time during this procedure
you need help, call Grizzly Tech Support at (570)
546-9663.
Summary of Contents for G0568