Model G0580 (Mfd. Since 11/06)
-11-
Voltage Conversion to 230V
The voltage conversion MUST be performed by
an electrician or qualified service personnel.
The voltage conversion procedure consists of
rewiring the motor and installing the correct plug.
A wiring diagram is provided on
Page 54 for your
reference.
IMPORTANT: If the diagram included on the
motor conflicts with the one on
Page 54, the motor
may have changed since the manual was printed.
Use the diagram included on the motor instead.
Items Needed
Qty
•
Phillips Head Screwdriver #2 ..................... 1
•
Electrical Tape ............................ As Needed
•
Wire Nut (14 AWG x 3) ............................... 1
•
Plug 6-15 .................................................... 1
4. Use wire nuts to connect the wires as indi-
cated in
Figure 5. Twist the wire nuts onto
their respective wires and secure them to
the wires with electrical tape so they will not
come loose.
Neutral
Hot
Ground
110 VAC
220 VAC
5-15 Plug
(Pre-wired)
Hot
Hot
6-15 Plug
(As Recommended)
220
VAC
G
Rewired for 220V
PADDLE SWITCH
(viewed from behind)
Motor
Pre-wired
for 110V
Ground
4
2
1
3
Start Capacitor
200MFD 125VAC
Run Capacitor
25MFD 250VAC
Motor
Rewired
for 220V
Ground
4
2
1
3
Rewired for 220V
Start Capacitor
200MFD 125VAC
Run Capacitor
25MFD 250VAC
Ground
5. Close and secure the motor junction box.
6. Install a 6-15 plug on the power cord, accord-
ing to the plug manufacturer's instructions. If
the plug manufacturer's instructions are not
available, NEMA standard 6-15 plug wiring is
provided on
Page 54.
Figure 5. Saw motor rewired to 230V.
Connect
Wires
with Nuts
Here
To convert the Model G0580 to 230V:
1. DISCONNECT SAW FROM POWER!
2. Remove the existing 5-15 plug.
3. Open the motor junction box, then loosen the
two wire nuts indicated in
Figure 4.
Neutral
Hot
Ground
110 VAC
220 VAC
5-15 Plug
(Pre-wired)
Hot
Hot
6-15 Plug
(As Recommended)
220
VAC
G
Rewired for 220V
PADDLE SWITCH
(viewed from behind)
Motor
Pre-wired
for 110V
Ground
4
2
1
3
Start Capacitor
200MFD 125VAC
Run Capacitor
25MFD 250VAC
Motor
Rewired
for 220V
Ground
4
2
1
3
Rewired for 220V
Start Capacitor
200MFD 125VAC
Run Capacitor
25MFD 250VAC
Ground
Figure 4. Location of wire nuts to be loosened.
Loosen
These
Wire Nuts
Summary of Contents for G0580
Page 15: ...Model G0580 Mfd Since 11 06 13 Hardware Recognition Chart...
Page 64: ......