-10-
Model G0671/G0672/G0673 (Mfd. Since 6/17)
The information contained herein is deemed accurate as of 11/27/2017 and represents our most recent product specifications.
Due to our ongoing improvement efforts, this information may not accurately describe items previously purchased.
PAGE 1 OF 2
Model G0673
MACHINE DATA
SHEET
Customer Service #: (570) 546-9663 · To Order Call: (800) 523-4777 · Fax #: (800) 438-5901
MODEL G0673 10 HP INDUSTRIAL DUST COLLECTOR
Product Dimensions:
Weight.............................................................................................................................................................. 410 lbs.
Width (side-to-side) x Depth (front-to-back) x Height......................................................................... 61 x 61 x 134 in.
Footprint (Length x Width)............................................................................................................................ 61 x 61 in.
Shipping Dimensions:
Type............................................................................................................................ Cardboard Box & Wood Frame
Content........................................................................................................................................................... Machine
Weight.............................................................................................................................................................. 472 lbs.
Length x Width x Height....................................................................................................................... 53 x 46 x 31 in.
Must Ship Upright................................................................................................................................................... Yes
Electrical:
Power Requirement..................................................................................................... 220V or 440V, 3-Phase, 60 Hz
Prewired Voltage.................................................................................................................................................. 220V
Full-Load Current Rating..................................................................................................... 30A at 220V, 15A at 440V
Minimum Circuit Size.......................................................................................................... 40A at 220V, 20A at 440V
Connection Type........................................................................................... Permanent (Hardwire to Shutoff Switch)
Switch Type.................................................................................................... Magnetic Switch w/Overload Protection
Voltage Conversion Kit.................................................................................................................. P0508037 for 440V
Recommended Phase Converter....................................................................................................................... G7979
Motors:
Main
Horsepower.............................................................................................................................................. 10 HP
Phase.................................................................................................................................................... 3-Phase
Amps..................................................................................................................................................... 30A/15A
Speed................................................................................................................................................ 3450 RPM
Type........................................................................................................................................... TEFC Induction
Power Transfer ............................................................................................................................... Direct Drive
Bearings..................................................................................................... Shielded & Permanently Lubricated
Main Specifications:
Operation
Dust Collector Type....................................................................................................................... Single-Stage
Approved Dust Types................................................................................................................................ Wood
Filter Type.................................................................................................................................................... Bag
Airflow Performance.......................................................................................................................... 5360 CFM
Max Static Pressure (at 0 CFM)............................................................................................................. 17.9 in.
Main Inlet Size........................................................................................................................................... 10 in.
Inlet Adapter Included.................................................................................................................................. Yes
Number of Adapter Inlets.................................................................................................................................. 5
Adapter Inlet Size........................................................................................................................................ 4 in.
Machine Collection Capacity At One Time....................................................................................................... 4
Maximum Material Collection Capacity................................................................................................. 48 cu. ft.
Filtration Rating.................................................................................................................................. 2.5 Micron