-24-
Model G0671/G0672/G0673 (Mfd. Since 6/17)
Note: The Model G0673 is a three-phase
machine. If it is wired out of phase, the
machine may not function properly. Proceed
to
Test Run on Page 26 to determine if your
machine is wired in phase, then proceed to
Step 7.
The Models G0671 and G0672 are single
phase and cannot be wired out of phase. For
these models, continue below.
7. Attach the inlet to the top of the impeller
housing with the #10-24 x 3/8" Phillips head
screw, as shown in
Figure 12.
Figure 12. Inlet mounted on impeller housing.
Phillips
Head Screw
8. Secure the hanger into the hanger sup-
port with one (Model G0673) or two (Model
G0671/G0672)
1
⁄
4
"-20 x
1
⁄
2
"
hex bolts (see
Figure 13).
10. Align the hanger assembly so that the hook is
directly over the center of the collector.
11. Repeat Steps 8–10 for the remaining hanger
assemblies.
12. Place the loop at the top of each upper col-
lection bag over each hook on the hanger
assemblies (see
Figure 15).
9. Mount the hanger assembly on the protruding
rod on the collector with one (Model G0671/
G0672) or two (Model G0673)
1
⁄
4
"-20 x
1
⁄
2
"
hex bolts, as shown in
Figure 14.
Figure 15. Upper filter bag mounted on hanger
assembly.
Bag Loop
Hanger
Assembly
Hook
Figure 13. Hanger attached to hanger support
(G0671/G0672 shown).
Hanger
Hanger Support
Hex Bolts
1
⁄
4
"-20 x
1
⁄
2
"
Figure 14. Hanger assembly mounted onto
collector (G0671/G0672).
Hanger
Assembly
Hex Bolt